ArticleSensors (Basel, Switzerland)2025
Integrated Lower Limb Robotic Orthosis with Embedded Highly Oriented Electrospinning Sensors by Fuzzy Logic-Based Gait Phase Detection and Motion Control.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Smart exoskeleton-assisted rehabilitation after fracture surgery: closed-loop control, personalized load management, and integrated telemonitoring.Frontiers in bioengineering and biotechnology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
This study introduces an integrated lower limb robotic orthosis with near-field electrospinning (NFES) piezoelectric sensors and a fuzzy logic-based gait phase detection system to enhance mobility assistance and rehabilitation. The exoskeleton incorporates embedded pressure sensors within the insoles to capture ground reaction forces (GRFs) in real-time. A fuzzy logic inference system processes these signals, classifying gait phases such as stance, initial contact, mid-stance, and pre-swing. The NFES technique enables the fabrication of highly oriented nanofibers, improving sensor sensitivity and reliability. The system employs a master-slave control framework. A Texas Instruments (TI) TMS320F28069 microcontroller (Texas Instruments, Dallas, TX, USA) processes gait data and transmits actuation commands to motors and harmonic drives at the hip and knee joints. The control strategy follows a three-loop methodology, ensuring stable operation. Experimental validation assesses the system's accuracy under various conditions, including no-load and loaded scenarios. Results demonstrate that the exoskeleton accurately detects gait phases, achieving a maximum tracking error of 4.23% in an 8-s gait cycle under no-load conditions and 4.34% when tested with a 68 kg user. Faster motion cycles introduce a maximum error of 6.79% for a 3-s gait cycle, confirming the system's adaptability to dynamic walking conditions. These findings highlight the effectiveness of the developed exoskeleton in interpreting human motion intentions, positioning it as a promising solution for wearable rehabilitation and mobility assistance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.