Evidence map›Paper›PMID 40096399›Full record

ArticleSensors (Basel, Switzerland)2025

Development and Testing of a Novel Microstrip Photocathode ICCD for Lunar Remote Raman Detection.

Haiting Zhao, Xiangfeng Liu, Chao Chen, Weiming Xu, Jianan Xie, Zhenqiang Zhang, Ziqing Jiang, Xuesen Xu, Zhiping He, Rong Shu and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Haiting ZhaoKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.ORCID 0009-0002-9217-8895
Xiangfeng LiuKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.ORCID 0000-0002-6821-449X
Chao ChenNorthern Night Vision Technology Co., Ltd., Kunming 650217, China.
Weiming XuKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.
Jianan XieKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.
Zhenqiang ZhangKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.
Ziqing JiangKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.
Xuesen XuSchool of Physics and Optoelectronic Engineering, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310024, China.
Zhiping HeKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.ORCID 0000-0003-3988-7369
Rong ShuKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.ORCID 0000-0002-3620-4617
Jianyu WangKey Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (CAS), Shanghai 200083, China.ORCID 0000-0001-6611-8528

Funding

National Science Foundation of China 62375278National Science Fund for Distinguished Young Scholars 62125505Natural Science Foundation of Shanghai Municipality 23ZR1473200
6 · The paper itself

Abstract

The intensified charge-coupled device (ICCD), known for its exceptional low-light detection performance and time-gating capability, has been widely applied in remote Raman spectroscopy systems. However, existing ICCDs face significant challenges in meeting the comprehensive requirements of high gating speed, high sensitivity, high resolution, miniaturization, and adaptability to extreme environments for the upcoming lunar remote Raman spectroscopy missions. To address these challenges, this study developed a microstrip photocathode (MP-ICCD) specifically designed for lunar remote Raman spectroscopy. A comprehensive testing method was also proposed to evaluate critical performance parameters, including optical gating width, optimal gain voltage, and relative resolution. The MP-ICCD was integrated into a prototype remote Raman spectrometer equipped with a 40 mm aperture telescope and tested under outdoor sunlight conditions. The experimental results demonstrated that the developed MP-ICCD successfully achieved a minimum optical gating width of 6.0 ns and an optimal gain voltage of 870 V, with resolution meeting the requirements for Raman spectroscopy detection. Under outdoor solar illumination, the prototype remote Raman spectrometer utilizing the MP-ICCD accurately detected the Raman spectra of typical lunar minerals, including quartz, olivine, pyroxene, and plagioclase, at a distance of 1.5 m. This study provides essential technical support and experimental validation for the application of MP-ICCD in lunar Raman spectroscopy missions.

Indexed as

ICCDimage intensifierlunar explorationRaman spectroscopytime gating

Identifiers

PMID40096399
PMCPMC11902724

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.