Evidence map›Paper›PMID 40096353›Full record

SynthesisSensors (Basel, Switzerland)2025

Pressure Sensors for Measuring Tibiofemoral Contact Mechanics in Meniscal Root Repair: A Systematic Review.

Khalis Boksh, Beibit Bashabayev, Duncan E T Shepherd, Daniel M Espino, Arijit Ghosh, Randeep Aujla, Tarek Boutefnouchet

Abstract readSystematic Review
In one paragraph

Synthesis in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Khalis BokshDepartment of Biomedical Engineering, University of Birmingham, Birmingham B15 2TT, UK.
Beibit BashabayevDepartment of Trauma and Orthopaedics, Morriston Hospital, Swansea SA6 6NL, UK.
Duncan E T ShepherdDepartment of Biomedical Engineering, University of Birmingham, Birmingham B15 2TT, UK.ORCID 0000-0002-2810-7075
Daniel M EspinoDepartment of Biomedical Engineering, University of Birmingham, Birmingham B15 2TT, UK.ORCID 0000-0001-7608-5619
Arijit GhoshLeicester Academic Knee Unit, University Hospitals of Leicester NHS Trust, Leicester LE1 5WW, UK.
Randeep AujlaLeicester Academic Knee Unit, University Hospitals of Leicester NHS Trust, Leicester LE1 5WW, UK.ORCID 0000-0001-8465-8923
Tarek BoutefnouchetLeicester Academic Knee Unit, University Hospitals of Leicester NHS Trust, Leicester LE1 5WW, UK.

Funding

Orthopaedic Research UK 2023Royal College of Surgeons of Edinburgh 2023
6 · The paper itself

Abstract

backgroundTibiofemoral contact mechanics (TFCM) is an accepted biomechanical metrics for evaluating the meniscus in its intact, torn, and repaired states. Pressure sensors are increasingly used, with accuracy and repeatability influenced by test conditions, their design, and their properties. To identify factors optimising performance, we performed a systematic review of the literature on their use for measuring TFCM in posterior meniscal root tears.

methodsThe Cochrane Controlled Register of Trials, PubMed, and Embase were used to perform a systematic review using the PRISMA criteria. As laboratory and surgical setup can influence sensor performance, we collected data on specimen preparation, repair techniques, hardware use, and biomechanical testing parameters.

results24 biomechanical studies were included. Specimen preparations were similar across studies with respect to femoral and tibial mounting. Single axial compressive forces were applied between 100 and 1800 N at varying flexion angles (0-90°). Tekscan (Boston, MA, USA) was the commonest sensor used to measure TFCM, followed by digital capacitive sensors and Fujifilm (Tokyo, Japan). Factors influencing their performance included fluid exposure, lack of adequate fixation, non-specific calibration protocols, load saturation exceeding calibration, damaged sensels and inappropriate pre-test conditioning.

conclusionsUnderstanding potential factors influencing pressure sensors may improve accuracy, area, and pressure distribution measurements.

Indexed as

FemurMenisci, TibialTibiaBiomechanical PhenomenaHumansPressureTibiofemoral Jointbiomechanicscontact areacontract pressureposterior meniscal root tearpressure sensorstibiofemoral contact mechanics

Identifiers

PMID40096353
PMCPMC11902513

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.