Evaluation of In-Ear and Fingertip-Based Photoplethysmography Sensors for Measuring Cardiac Vagal Tone Relevant Heart Rate Variability Parameters.

Ankit Parikh, Gwyn Lewis, Hamid GholamHosseini, Usman Rashid, David Rice, Faisal Almesfer

Abstract readEvaluation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ankit ParikhSchool of Clinical Sciences, Auckland University of Technology, Auckland 0627, New Zealand.ORCID 0009-0001-8014-5781
Gwyn LewisDepartment of Physiotherapy, Auckland University of Technology, Auckland 0627, New Zealand.ORCID 0000-0001-9324-0940
Hamid GholamHosseiniDepartment of Electrical and Electronic Engineering, Auckland University of Technology, Auckland 1010, New Zealand.ORCID 0000-0002-0135-2687
Usman RashidCentre for Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand.ORCID 0000-0002-1109-5493
David RiceHealth and Rehabilitation Research Institute, Auckland University of Technology, Auckland 0627, New Zealand.ORCID 0000-0002-3327-8776
Faisal AlmesferExsurgo Ltd., 45i William Pickering Drive, Rosedale, Auckland 0632, New Zealand.ORCID 0000-0002-5924-0135

Funding

Exsurgo Ltd N/A
6 · The paper itself

Abstract

This paper presents a study undertaken to evaluate the sensor systems that were shortlisted to be used in the development of a portable respiratory-gated transcutaneous auricular vagus nerve stimulation (taVNS) system. To date, all published studies assessing respiratory-gated taVNS have been performed in controlled laboratory environments. This limitation arises from the reliance on non-portable sensing equipment, which poses significant logistical challenges. Therefore, we recognised a need to develop a portable sensor system for future research, enabling participants to perform respiratory-gated stimulation conveniently from their homes. This study aimed to measure the accuracy of an in-ear and a fingertip-based photoplethysmography (PPG) sensor in measuring cardiac vagal tone relevant heart rate variability (HRV) parameters of root mean square of successive R-R interval differences (RMSSDs) and the high-frequency (HF) component of HRV. Thirty healthy participants wore the prototype sensor equipment and the gold standard electrocardiogram (ECG) equipment to record beat-to-beat intervals simultaneously during 10 min of normal breathing and 10 min of deep slow breathing (DSB). Additionally, a stretch sensor was evaluated to measure its accuracy in detecting exhalation when compared to the gold standard sensor. We used Bland-Altman analysis to establish the agreement between the prototypes and the ECG system. Intraclass correlation coefficients (ICCs) were calculated to establish consistency between the prototypes and the ECG system. For the stretch sensor, the true positive rate (TPR), false positive rate (FPR), and false negative rate (FNR) were calculated. Results indicate that while ICC values were generally good to excellent, only the fingertip-based sensor had an acceptable level of agreement in measuring RMSSDs during both breathing phases. Only the fingertip-based sensor had an acceptable level of agreement during normal breathing in measuring HF-HRV. The study highlights that a high correlation between sensors does not necessarily translate into a high level of agreement. In the case of the stretch sensor, it had an acceptable level of accuracy with a mean TPR of 85% during normal breathing and 95% during DSB. The results show that the fingertip-based sensor and the stretch sensor had acceptable levels of accuracy for use in the development of the respiratory-gated taVNS system.

Indexed as

Ear AuricleFingersHeart Rate DeterminationPhotoplethysmographyVagus NerveAdolescentAdultAgedElectrocardiographyFemaleHealthy VolunteersHeart RateHumansMaleMiddle AgedPilot Projectscardiac vagal tonefingertipheart rate variability (HRV)high-frequency HRV (HF-HRV)in-earphotoplethysmography (PPG)root mean square of successive R-R interval differences (RMSSDs)

Identifiers

PMID40096338
PMCPMC11902391

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.