ArticleSensors (Basel, Switzerland)2025
Subspace-Based Two-Step Iterative Shrinkage/Thresholding Algorithm for Microwave Tomography Breast Imaging.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Microwave tomography serves as a promising non-invasive technique for breast imaging, yet accurate reconstruction in noisy environments remains challenging. We propose an adaptive subspace-based two-step iterative shrinkage/thresholding (S-TwIST) algorithm that enhances reconstruction accuracy through two key innovations: a singular value decomposition (SVD) approach for extracting deterministic contrast sources, and an adaptive strategy for optimal singular value selection. Unlike conventional DBIM methods that rely solely on secondary incident fields, S-TwIST incorporates deterministic induced currents to achieve more accurate total field approximation. The algorithm's performance is validated using both synthetic "Austria" profiles and 45 digital breast phantoms derived from the UWCEM repository. The results demonstrate robust reconstruction capabilities across varying noise levels (0-20 dB SNR), achieving average relative errors of 0.4847% in breast tissue reconstruction without requiring prior noise level knowledge. The algorithm successfully recovers complex tissue structures and density distributions, showing potential for clinical breast imaging applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials