Evidence map›Paper›PMID 40096215›Full record

ArticleSensors (Basel, Switzerland)2025

Imbalanced Power Spectral Generation for Respiratory Rate and Uncertainty Estimations Based on Photoplethysmography Signal.

Soojeong Lee, Mugahed A Al-Antari, Gyanendra Prasad Joshi, Yeong Hyeon Gu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Soojeong LeeDepartment of Computer Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea.
Mugahed A Al-AntariDepartment of Artificial Intelligence and Data Science, Sejong University, Seoul 05006, Republic of Korea.ORCID 0000-0002-4457-4407
Gyanendra Prasad JoshiDepartment of AI Software, Kangwon National University, Samcheok 10587, Kangwon State, Republic of Korea.ORCID 0000-0002-5446-288X
Yeong Hyeon GuDepartment of Artificial Intelligence and Data Science, Sejong University, Seoul 05006, Republic of Korea.ORCID 0000-0002-0002-9386

Funding

NRF 1711160571
6 · The paper itself

Abstract

Respiratory rate (RR) changes in the elderly can indicate serious diseases. Thus, accurate estimation of RRs for cardiopulmonary function is essential for home health monitoring systems. However, machine learning (ML) algorithm errors embedded in health monitoring systems can be problematic in medical decision-making because some data have much larger sample sizes in the training set than others. This difference in sample size implies biosignal data imbalance. Therefore, we propose a novel methodology that combines bootstrap-based imbalanced continuous power spectral generation (IPSG) with ML approaches to estimate RRs and uncertainty to address data imbalance. The sample differences between normal breathing (12-20 breaths per minute (brpm)), dyspnea (≥20 brpm), and hypopnea (<8 brpm) show significant data imbalance, which can affect the learning of ML algorithms. Hence, the normal breathing part with a large amount of data is well-trained. In contrast, the dyspnea and hypopnea parts with relatively fewer data are not well-trained, and this data imbalance makes it difficult to estimate the reference variables of the actual dyspnea and hypopnea data parts, thus generating significant errors. Hence, we apply ML models by mixing artificial feature curves generated using a bootstrap model with the original feature curves to estimate RRs and solve this problem. As a result, the nonparametric bootstrap approach significantly increases the number of artificial feature curves. The generated artificial feature curves are selectively utilized in the highly imbalanced parts. Therefore, we confirm that IPSG is efficiently trained to predict the complex nonlinear relationship between the feature vectors obtained from the photoplethysmography signal and the reference RR. The proposed methodology shows more accurate prediction performance and uncertainty. Combining the proposed Gaussian process regression (GPR) with IPSG based on the Beth Israel Deaconess Medical Center dataset, the mean absolute error of the RR is 0.79 and 1.47 brpm. Our approach achieves high stability and accuracy by randomly mixing original and artificial feature curves. The proposed GPR-IPSG model can improve the performance of clinical home-based monitoring systems and design a reliable framework.

Indexed as

PhotoplethysmographyRespiratory RateAgedAlgorithmsDyspneaFemaleHumansMachine LearningMaleMonitoring, PhysiologicSignal Processing, Computer-AssistedUncertaintybootstrapphotoplethysmographypower spectral curvesrespiratory rate estimationuncertainty

Identifiers

PMID40096215
PMCPMC11902385

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.