Evidence map›Paper›PMID 40096200›Full record

ArticleSensors (Basel, Switzerland)2025

Dimensionality Reduction and Electrode Arrangement Optimization for an Electric Field Source Seeking Surgical Navigation Method.

Yuxin Fang, Fan Yang, Wei He, Xing Li, Xinheng Li

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yuxin FangSchool of Electrical Engineering, Chongqing University, Chongqing 400044, China.ORCID 0009-0004-7699-5160
Fan YangSchool of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Wei HeSchool of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Xing LiSchool of Electrical Engineering, Chongqing University, Chongqing 400044, China.ORCID 0009-0006-6864-7988
Xinheng LiSchool of Electrical Engineering, Chongqing University, Chongqing 400044, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study proposes a Dimensionality Reduction Electric Field Source Seeking (EFSS) method for real-time, high-precision navigation in intracranial puncture surgeries. The method integrates internal localization electrodes and external potential measurement electrodes to minimize surgical trauma while ensuring the accurate localization and guidance of surgical instruments. To optimize the electrode arrangement, two evaluation metrics-Mean Response Coefficient (MRC) and MRC-mean-were introduced. The simulation results demonstrated the effectiveness of these metrics, with the optimal arrangement achieving an average localization error below 2 mm and a 56% reduction in error after optimization. Experimental validation was conducted using a brain model with conductivity properties similar to those of human tissue. Localization experiments confirmed the robustness and accuracy of the EFSS method, with all results showing consistent repeatability and monotonic trends in performance across different electrode configurations. This study highlights the potential of the dimensionality reduction EFSS method as a novel and effective approach for navigation in minimally invasive intracranial surgeries.

Indexed as

BrainSurgical Navigation SystemsDimensionality ReductionElectrodesHumansbiomedical sensorselectric fieldelectrode arrangementsurgical navigation

Identifiers

PMID40096200
PMCPMC11902705

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.