Evidence map›Paper›PMID 40096101›Full record

ArticleSensors (Basel, Switzerland)2025

Investigation of Trajectory Tracking Control in Hip Joints of Lower-Limb Exoskeletons Using SSA-Fuzzy PID Optimization.

Wei Li, Xiaojie Wei, Dawen Sun, Siyu Zong, Zhengwei Yue

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wei LiCollege of Mechanical and Vehicle Engineering, Changchun University, Changchun 130022, China.
Xiaojie WeiCollege of Mechanical and Vehicle Engineering, Changchun University, Changchun 130022, China.
Dawen SunCollege of Computer Science and Technology, Changchun University, Changchun 130022, China.
Siyu ZongCollege of Mechanical and Vehicle Engineering, Changchun University, Changchun 130022, China.ORCID 0009-0004-4408-6106
Zhengwei YueShandong Jite Industrial Technology Co., Ltd., Rizhao 276800, China.

Funding

Capital construction funds in the 2024 budget of Jilin Provincial Development and Reform Com-mission 2024c009-6
6 · The paper itself

Abstract

The application of lower-limb exoskeleton robots in rehabilitation is becoming more prevalent, where the precision of control and the speed of response are essential for effective movement tracking. This study tackles the challenge of optimizing both control accuracy and response speed in trajectory tracking for lower-limb exoskeleton hip robots. We introduce an optimization strategy that integrates the Sparrow Search Algorithm (SSA) with fuzzy Proportional-Integral-Derivative (PID) control. This approach addresses the inefficiencies and time-consuming process of manual parameter tuning, thereby improving trajectory tracking performance. First, recognizing the complexity of hip joint motion, which involves multiple degrees of freedom and intricate dynamics, we employed the Lagrangian method. This method is particularly effective for handling nonlinear systems and simplifying the modeling process, allowing for the development of a dynamic model for the hip joint. The SSA is subsequently utilized for the online self-tuning optimization of both the proportional and quantization factors within the fuzzy PID controller. Simulation experiments confirm the efficacy of this strategy in tracking hip joint trajectories during flat walking and standing hip flexion rehabilitation exercises. Experimental results from diverse test populations demonstrate that SSA-fuzzy PID control improves response times by 27.8% (for flat walking) and 30% (for standing hip flexion) when compared to traditional PID control, and by 6% and 2%, respectively, relative to fuzzy PID control. Regarding tracking accuracy, the SSA-fuzzy PID approach increases accuracy by 81.4% (for flat walking) and 80% (for standing hip flexion) when compared to PID control, and by 57.5% and 56.8% relative to fuzzy PID control. The proposed strategy significantly improves both control accuracy and response speed, offering substantial theoretical support for rehabilitation training in individuals with lower-limb impairments. Moreover, in comparison to existing methods, this approach uniquely tackles the challenges of parameter tuning and optimization, presenting a more efficient solution for trajectory tracking in exoskeleton systems.

Indexed as

Exoskeleton DeviceHip JointLower ExtremityAdultAlgorithmsBiomechanical PhenomenaFuzzy LogicHumansMaleRange of Motion, ArticularRoboticsWalkingfuzzy PID controllower-limb exoskeletonSparrow Search Algorithmtrajectory tracking

Identifiers

PMID40096101
PMCPMC11902423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.