Evidence map›Paper›PMID 40096079›Full record

ArticleSensors (Basel, Switzerland)2025

Enhancing Orthotic Treatment for Scoliosis: Development of Body Pressure Mapping Knitwear with Integrated FBG Sensors.

Ka-Po Lee, Zhijun Wang, Lin Zheng, Ruixin Liang, Queenie Fok, Chao Lu, Linyue Lu, Jason Pui-Yin Cheung, Kit-Lun Yick, Joanne Yip

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ka-Po LeeSchool of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong 999077, China.ORCID 0000-0001-6013-3401
Zhijun WangFoshan Fifth People's Hospital (Foshan Rehabilitation Hospital), Foshan 528211, China.
Lin ZhengSchool of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong 999077, China.ORCID 0009-0000-1135-7871
Ruixin LiangSchool of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong 999077, China.
Queenie FokSchool of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong 999077, China.
Chao LuPhotonics Research Institute, Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China.
Linyue LuPhotonics Research Institute, Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, Hong Kong 999077, China.ORCID 0000-0003-1694-1094
Jason Pui-Yin CheungDepartment of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong 999077, China.ORCID 0000-0002-7052-0875
Kit-Lun YickSchool of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong 999077, China.
Joanne YipSchool of Fashion and Textiles, The Hong Kong Polytechnic University, Hong Kong 999077, China.ORCID 0000-0002-3270-4702

Funding

Departmental Grant of the School of Fashion and Textiles, The Hong Kong Polytechnic University PolyU RPPUResearch Impact Fund 3-RC53
6 · The paper itself

Abstract

Bracing is a widely used conservative treatment for adolescent idiopathic scoliosis (AIS) patients, yet there is no consensus on the optimal amount of force applied. Although a number of different sensors have been developed to continuously monitor the applied pressure and force, they have several limitations, including inadequate overall force distribution and displacement. They also cause discomfort with limited wearability. In this study, body pressure mapping knitwear (BPMK) integrated with fourteen silicone-embedded fiber Bragg grating (FBG) sensors is developed to monitor immediate and overall changes in force during the bracing treatment. A wear trial of the BPMK is conducted by using a validated soft AIS mannequin, and prediction equations have been formulated for the FBG sensors at individual locations. The findings indicate that the measured forces are in good agreement with those obtained from clinical studies, with peak forces around the padding regions reaching approximately 2N. This was further validated by using finite element (FE) models. When comparing X-ray images, the estimated differences in Cobb angles were found to be 0.6° for the thoracic region and 2.1° for the lumbar region. This model is expected to provide valuable insights into optimal force application, thus minimizing the risk of injury and enhancing bracing compliance and efficacy. Ultimately, this innovative approach provides clinicians with data-driven insights for safer and more effective bracing applications, thus improving the quality of life of AIS patients.

Indexed as

Orthotic DevicesScoliosisAdolescentBracesFinite Element AnalysisHumansPressurefiber Bragg gratingforce monitoringhealth monitoringinlayknitted undergarmentsoptical fiber sensorpressure monitoringscoliosissmart textiles

Identifiers

PMID40096079
PMCPMC11902499

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.