ArticleJournal of biomechanical engineering2025
Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures.
Article in Journal of biomechanical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Multiscale Architecture Governs Stability in Suction-Actuated Variable Stiffness Catheters.Journal of biomechanical engineering · 2026Article
- Mechanically adaptive materials with tunable stiffness for biomedical devices: Mechanisms, applications, and perspectives.Materials today. Bio · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors.
Funding
Abstract
Endovascular procedures require sheaths with contradictory mechanical properties: flexibility for navigation through tortuous vessels, yet rigidity for device delivery. Current approaches rely on multiple device exchanges, increasing procedural time, and complication risks. Here we present a novel endovascular sheath design scheme with dynamically controllable flexural rigidity along its entire length. The device incorporates axially aligned metal string arrays between inner and outer lumens, enabling transition between flexible and rigid states through suction actuation. Three-point bend testing demonstrated that actuation increases flexural rigidity from the range associated with diagnostic catheters to that associated with support sheaths. In simulated contralateral access procedures, the device reduced access time to 1/3 of the time required when using conventional approaches. in vivo porcine studies validated the sheath's ability to navigate tortuous anatomy in its flexible state and successfully support advancement of increasingly rigid therapeutic devices when actuated. Technology enables single-sheath delivery of treatment, potentially reducing procedural complexity, decreasing complication rates, and improving patient outcomes across various endovascular interventions. This design represents a promising approach to combining catheter and sheath design that benefits both peripheral and neurovascular procedures.