Evidence map›Paper›PMID 40094319›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2025

Efficacy of endovascular circulating false lumen occlusion in chronic aneurysmal descending aortic dissections

Emeric Gremen, Mathieu Finas, Eliott Mathieu, Frédéric Thony, Mathieu Rodiere, Julien Ghelfi

Abstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Emeric GremenGrenoble-Alpes University Faculty of Medicine, Department of Radiology, Grenoble, FranceORCID 0000-0002-2633-8937
Mathieu FinasGrenoble Alpes University Hospital, Department of Radiology, Grenoble, France
Eliott MathieuGrenoble Alpes University Hospital, Department of Radiology, Grenoble, FranceORCID 0009-0002-4535-8842
Frédéric ThonyGrenoble Alpes University Hospital, Department of Radiology, Grenoble, FranceORCID 0000-0002-7102-7169
Mathieu RodiereGrenoble Alpes University Hospital, Department of Radiology, Grenoble, France
Julien GhelfiGrenoble-Alpes University Faculty of Medicine, Department of Radiology, Grenoble, FranceORCID 0000-0002-9039-6488

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the efficacy of endovascular circulating false lumen occlusion (CFLO) in inducing positive aortic remodeling in chronic aneurysmal descending aortic dissection (AD).

methodsThis retrospective monocentric study included patients treated by CFLO between 2003 and 2022 in the context of chronic AD with progressive descending aneurysmal evolution and persistent circulating false lumen (FL). The procedure was achieved with coils, plugs, and/or glue at the entry tear or in the FL and/or with covered stenting in the supra-aortic trunk. The primary endpoint evaluated the positive aortic remodeling, defined as stabilization or a decrease in the aortic diameter on a computed tomography scan at the 1-year follow-up after the procedure. The FL circulating status, safety, and occurrence of aneurysm events during follow-up were also evaluated.

resultsTwenty patients [median age: 65.4 years, interquartile range (IQR): 58.4–69.9; 13 men] were included, with a median duration from an acute AD of 32.5 months (IQR: 8.8–76.5). Twelve patients (60%) achieved complete FL thrombosis after CFLO, whereas 8/20 patients (40.0%) experienced partial thrombosis. Additionally, positive aortic remodeling was observed in 13 patients (65%). Following the procedure, the aneurysmal aortic diameter decreased in 8/20 patients (40.0%) and remained stable in 5/20 patients (25.0%). Two patients (10%) had complications related to the procedure. Two patients (10%) had secondary aneurysm events during follow-up.

conclusionCFLO is a feasible and efficient method to induce FL thrombosis and reduce aneurysmal progression in chronic AD. CLINICAL SIGNIFICANCE: The positive outcomes observed highlight the potential of this technique to improve patient management in complex aortic pathologies. This approach offers a valuable option in the management of chronic AD and emphasizes the importance of endovascular interventions in enhancing patient outcomes.

Indexed as

Aortic Aneurysm, ThoracicAortic DissectionEndovascular ProceduresAgedChronic DiseaseFemaleHumansMaleMiddle AgedRetrospective StudiesStentsTomography, X-Ray ComputedTreatment OutcomeVascular Remodelingaortic aneurysmChronic aortic dissectioncirculating false aortic lumencoilsembolizationendovascular occlusionentry tearfalse lumenfalse lumen thrombosisglueplugsstentthoracic endovascular aortic repairtrue lumen

Identifiers

PMID40094319
PMCPMC12239530

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked