Evidence map›Paper›PMID 40094171›Full record

ArticleArtificial organs2025

Anatomic Suitability for Axillary Intra-Aortic Balloon Pump Circulatory Support.

Carlos Alberto Valdes, Kristin Drew, Omar M Sharaf, Mustafa M Ahmed, Alex M Parker, Juan R Vilaro, Juan M Aranda, Michael R Massoomi, R David Anderson, Yomary Jimenez and 1 more

Abstract read
In one paragraph

Article in Artificial organs, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Carlos Alberto ValdesUniversity of Florida College of Medicine, Gainesville, Florida, USA.ORCID https://orcid.org/0000-0002-6156-1165
Kristin DrewUniversity of Florida College of Medicine, Gainesville, Florida, USA.
Omar M SharafUniversity of Florida College of Medicine, Gainesville, Florida, USA.
Mustafa M AhmedDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.ORCID https://orcid.org/0000-0003-2781-7873
Alex M ParkerDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.
Juan R VilaroDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.
Juan M ArandaDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.
Michael R MassoomiDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.
R David AndersonDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.
Yomary JimenezDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.
Mohammad A Z Al-AniDivision of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.

Funding

STUDENTS IN HEALTH PROFESSIONAL SCHOOLST35HL007489 · NHLBI · UNIVERSITY OF FLORIDA · PI Scott A Berceli, Robert Maile · 1985 to 2026
$2.4M
NHLBI NIH HHS T35 HL007489NIH HHS
6 · The paper itself

Abstract

backgroundIntra-aortic balloon pumps (IABP) are commonly used as a bridge to heart transplant (Htx). Although IABPs were designed for transfemoral arterial placement, axillary IABPs (axIABP) allow for continued ambulation and rehabilitation. However, increased rates of device complications with axillary compared to femoral insertion suggest anatomic variations that predispose patients to device failure.

methodsWe conducted a single-center retrospective study of patients who received axIABP as a bridge to HTx between February 2018 and July 2022. Pre-axIABP computed tomography (CT) images were reviewed for all patients, and anatomic features of the axillary and central arteries were measured and correlated with mechanical axIABP complications.

resultsA total of 48 patients underwent successful axIABP placement with available pre-insertion CT images, of whom 35 (72.9%) were male. Out of 48 patients, 26 (54.2%) experienced 34 complications, including axIABP rupture (n = 10, 29%), infection (n = 8, 23%), and thrombosis (n = 6, 18%). CTs showed an average axillary artery diameter and depth of 6.79 and 55.6 mm, respectively. The average subclavian artery takeoff angle from the aortic arch was 95.4°.

conclusionOf the 10 vascular anatomic features measured, there was no association between any single measurement and axIABP complications. However, there may be other structural features not measured by routine CT, technical issues with insertion, and device factors not accounted for in this study that drive axIABP complications. Nonetheless, our findings suggest that normal variations in the measured vascular anatomy should not preclude axIABP use.

Indexed as

Axillary ArteryIntra-Aortic Balloon PumpingAdultAgedFemaleHeart-Assist DevicesHeart TransplantationHumansMaleMiddle AgedRetrospective StudiesTomography, X-Ray Computedaxillaryheart failureintra‐aortic balloon pumpmechanical circulatory support

Identifiers

PMID40094171
PMCPMC12181060

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.