Evidence map›Paper›PMID 40093914›Full record

ReviewChemistry of materials : a publication of the American Chemical Society2025

Guidelines for the Selection of Scintillators for Indirect Photon-Counting X-ray Detectors.

J Jasper van Blaaderen, Casper van Aarle, David Leibold, Pieter Dorenbos, Dennis R Schaart

Abstract readReview
In one paragraph

Review in Chemistry of materials : a publication of the American Chemical Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

J Jasper van BlaaderenDelft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Mekelweg 15, 2629 JB Delft, The Netherlands.ORCID https://orcid.org/0000-0003-1460-8319
Casper van AarleDelft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Mekelweg 15, 2629 JB Delft, The Netherlands.
David LeiboldDelft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Mekelweg 15, 2629 JB Delft, The Netherlands.
Pieter DorenbosDelft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Mekelweg 15, 2629 JB Delft, The Netherlands.
Dennis R SchaartDelft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Mekelweg 15, 2629 JB Delft, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

X-ray photon-counting detectors (PCDs) are a rapidly developing technology. Current PCDs used in medical imaging are based on CdTe, CZT, or Si semiconductor detectors, which directly convert X-ray photons into electrical pulses. An alternative approach is to combine ultrafast scintillators with silicon photomultipliers (SiPMs). Here, an overview is presented of different classes of scintillators, with the aim of assessing their potential application in scintillator-SiPM based indirect X-ray PCDs. To this end, three figures of merit (FOMs) are defined: the pulse intensity, the pulse duration, and the pulse quality. These FOMs quantify how characteristics such as light yield, pulse shape, and energy resolution affect the suitability of scintillators for application in indirect PCDs. These FOMs are based on emissive characteristics; a fourth FOM (ρZ

Identifiers

PMID40093914
PMCPMC11905209

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked