ArticleJournal of neuroendovascular therapy2025
Novel Flow Reversal Technique Using Dual-Balloon Inflation for Right Common Carotid Artery Stenosis: A Technical Case Report.
Article in Journal of neuroendovascular therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: Herein, we present a novel flow reversal technique using dual-balloon inflation that can provide enhanced catheter stability and reliable embolic protection for percutaneous antegrade stenting in a patient with right common carotid artery (CCA) stenosis. Case Presentation: A 75-year-old female patient with post-radiation right CCA stenosis initially underwent stenting using distal filter protection, which resulted in transient left upper limb paralysis caused by embolic infarction. After restenosis at 6 months, retreatment was performed using dual-balloon occlusion with the 9-F balloon guiding catheter in the innominate artery and the 8-F balloon guiding catheter in the right subclavian artery. Intraoperative ultrasonography confirmed a successful flow reversal, and debris was captured from the aspirated blood. The patient was discharged without neurological deficits, and postoperative imaging showed no new ischemic lesions. Conclusion: The novel flow reversal technique using dual-balloon inflation can be effective and safe for treating right CCA stenosis by achieving both reliable embolic protection and improved catheter stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.