ArticleFrontiers in cellular and infection microbiology2025
Establishment of a novel double-antibody sandwich fluorescence microsphere immunochromatographic test strip for rapid detection of swine acute diarrhea syndrome coronavirus (SADS-CoV) infection.
Article in Frontiers in cellular and infection microbiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Acid-Mediated Antimicrobial Activity and Probiotic Potential of an SKS1-knockout Saccharomyces Cerevisiae Strain.Probiotics and antimicrobial proteins · 2026Article
- Swine Enteric Coronaviruses: An Updated Overview of Epidemiology, Diagnosis, Prevention, and Control.Animals : an open access journal from MDPI · 2026Review
- Closed-loop artificial intelligence agents for animal epidemic prediction and decision support in livestock farming: a review.Frontiers in veterinary science · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Swine acute diarrhea syndrome coronavirus (SADS-CoV) is an enveloped, positive-sense, single-stranded RNA virus that causes clinical symptoms such as vomiting and diarrhea in 10-day-old piglets. SADS-CoV has caused significant economic losses in the swine industry in southern China. Currently, no effective treatments or vaccines are available for this disease, making it crucial to establish a point-of-care testing (POCT) technology for early diagnosis and prevention. Methods: In this study, we first validated the specificity and immunogenicity of four monoclonal antibodies (mAbs) targeting the nucleocapsid (N) protein of swine acute diarrhea syndrome coronavirus (SADS-CoV). The optimal antibody pair for constructing the fluorescent microsphere-based immunochromatographic assay (FM-ICA) was determined through systematic pairwise screening. Critical parameters of the FM-ICA test strip, including antibody labeling concentration, coating concentration, incubation time, and sample dilution ratio, were subsequently optimized. Analytical performance characteristics of the developed FM-ICA were then rigorously evaluated. Finally, clinical validation was conducted by parallel testing of 72 field samples using both FM-ICA and quantitative PCR (qPCR), followed by concordance rate analysis. Results: First, we demonstrated that all four monoclonal antibodies exhibited favorable immunogenicity and specificity. Subsequently, mAb 12E1 was identified as the coating antibody, and mAb 5G12 was selected as the labeled antibody, forming the optimal combination for FM-ICA preparation. After optimization, the ideal parameters were determined: a labeling concentration of 200 μg/mg for antibodies, a coating concentration of 1 mg/mL, an incubation time of 10 min, and a dilution factor of 10. The FM-ICA exhibited outstanding specificity, sensitivity, reproducibility, and stability, achieving a maximum detectable dilution factor of 1280 and a limit of detection (LOD) of 78 PFU mL⁻¹. Finally, the concordance rate between FM-ICA and qPCR for clinical samples reached 97.22%. Discussion: These results indicate that FM-ICA is an excellent POCT technology that can be used for the early diagnosis of SADS-CoV, providing support for disease prevention and treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.