ArticleJournal of orthopaedic case reports2025
Anterior Hip Dislocation Following Total Hip Arthroplasty, Caused by Broken Trial Femoral Head Particles: A Case Report.
Article in Journal of orthopaedic case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Dislocation is one of the most common causes of patient and surgeon dissatisfaction following total hip arthroplasty (THA). In this case, we describe the presence of broken plastic particles, originating from the plastic trial femoral head (TFH) which caused total hip dislocation. Case Report: A 67-year-old man with avascular necrosis of his left hip, who underwent a hybrid THA, dislocated his hip twice in the first 2 months after the initial surgery. A computed tomography scan revealed a well-oriented cup and stem and the presence of two dense intra-articular particles, later identified as the possible cause of dislocation. The particles were removed during revision surgery and were retrospectively determined to be broken TFH particles, made of hard plastic. Conclusion: We believe that the brittle design of certain TFH components is vulnerable to damage during perioperative trialing and testing; therefore, care must be taken to check the integrity of these devices during hip surgery. It is important to recognize the existence of such a rare complication.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.