ArticlePediatric research2025
Predicting optimal endotracheal tube depth in children based on height and middle finger length.
Article in Pediatric research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCurrent calculation formulas cannot accurately predict intubation depth in children due to variations in growth and development patterns and unique anatomical characteristics of the pediatric airway. This study aims to develop a method for determining the appropriate ETT insertion depth in pediatric patients.
methodsThis study included 205 patients aged 4-12 years who underwent elective surgery under general anesthesia with tracheal intubation. The general condition of the enrolled children was recorded, and growth parameters were measured preoperatively. Multivariate linear regression analysis was employed to develop a new formula for predicting intubation depth.
resultsThe novel multivariate-based formula was derived using height and middle finger length [D (cm) = 0.06 × height (cm) + 0.89 × middle finger length (cm) + 3.4] as reference variables. Bland-Altman analysis demonstrated mean differences between the optimal depth and ETT depth was -0.05 cm (95% LOA, -1.38 to 1.28 cm) for the new formula and 1.24 cm (95% LOA, -0.74 to 3.23 cm) for the traditional formula, respectively. This study demonstrated significant individual variations in tracheal intubation depth in pediatric patients.
conclusionThe height- and middle finger length-referenced formulas predicted the depth of intubation more accurate than the traditional age-based formula in pediatric patients. IMPACT: The prediction formula is effective in reducing the misalignment rate in children undergoing tracheal intubation under general anesthesia. The new formula, which incorporates both height and middle finger length, was found to predict the optimal endotracheal intubation depth with greater accuracy than the traditional formula. This provides an accurate and easy way for clinicians to calculate the depth of intubation.
Indexed as