A MEMS seismometer respiratory monitor for work of breathing assessment and adventitious lung sounds detection via deep learning.

Brian Sang, Haoran Wen, Greg Junek, Wendy Neveu, Lorenzo Di Francesco, Justin Romberg, Farrokh Ayazi

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Brian SangGeorgia Institute of Technology, Atlanta, GA, 30308, USA. bsang3@gatech.edu.
Haoran WenStethX Inc., Atlanta, GA, 30308, USA.
Greg JunekStethX Inc., Atlanta, GA, 30308, USA.
Wendy NeveuDepartment of Medicine, Emory University School of Medicine, Atlanta, GA, 30303, USA.
Lorenzo Di FrancescoDepartment of Medicine, Emory University School of Medicine, Atlanta, GA, 30303, USA.
Justin RombergGeorgia Institute of Technology, Atlanta, GA, 30308, USA.
Farrokh AyaziGeorgia Institute of Technology, Atlanta, GA, 30308, USA.

Funding

A Non-invasive, Wearable, Miniaturized Auscultation Device for Diagnosis of Pulmonary DiseasesR03EB029099 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI AYAZI, FARROKH · 2020 to 2021
$163k
NIBIB NIH HHS R03 EB029099NIH HHS R03 EB029099
6 · The paper itself

Abstract

Physicians evaluate a patient's respiratory health during a physical examination by visual assessment of the work of breathing (WoB) to determine respiratory stability, and by detecting abnormal lung sounds via lung auscultation using a stethoscope to identify common pathological lung diseases, such as chronic obstructive pulmonary disease (COPD) and pneumonia. Since these assessment methods are subjective, a low-profile device used for an accurate and quantitative monitoring approach could provide valuable preemptive insights into respiratory health, proving to be clinically beneficial. To achieve this goal, we have developed a miniature patch consisting of a sensitive wideband multi-axis seismometer that can be placed on the anatomical areas of a patient's lungs to enable an effective quantification of a patient's WoB and lung sounds. When used on a patch, the seismometer captures chest wall vibrations due to respiratory muscle effort, known as high-frequency mechanomyogram (MMG), during tidal breathing as well as seismic pulmonary-induced vibrations (PIVs) during deep breathing due to normal and/or adventitious lung sounds like crackles, while simultaneously recording respiration rate and phase. A system comprised of multiple patches was evaluated on 124 patients in the hospital setting and shown to accurately assess and quantify a patent's physical signs of WoB by measuring the average respiratory effort extracted from high-frequency MMG signals, demonstrating statistical significance of this method in comparison to clinical bedside observation of WoB and respiration rate. A data fusion deep learning model was developed which combined the inputs of PIVs lung sounds and the corresponding respiration phase to detect crackle, wheeze and normal breath sound features. The model exhibited high accuracy, sensitivity, specificity, precision and F1 score of 93%, 93%, 97%, 93% and 93% respectively, with area under the curve (AUC) of precision recall (PR) of 0.97 on the test set. Additionally, the PIVs with corresponding respiration phase captured from each auscultation point generated an acoustic map of the patient's lung, which correlated with traditional lung radiographic findings.

Indexed as

Deep LearningLungRespirationRespiratory SoundsAdultAgedAuscultationFemaleHumansMaleMiddle AgedMonitoring, PhysiologicPulmonary Disease, Chronic ObstructiveStethoscopes

Identifiers

PMID40089574
PMCPMC11910636

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.