Evidence map›Paper›PMID 40087363›Full record

ArticleScientific reports2025

A novel strategy for controllable electrofabrication of molecularly imprinted polymer biosensors utilizing embedded Prussian blue nanoparticles.

Bahareh Babamiri, Mohammadreza Farrokhnia, Mehdi Mohammadi, Amir Sanati Nezhad

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bahareh Babamiri *BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
Mohammadreza Farrokhnia *BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
Mehdi MohammadiDepartment of Biological Sciences, University of Calgary, 2500 University Drive, NW, Calgary, AB, T2N 1N4, Canada. mehdi.mohammadiashan@ucalgary.ca.
Amir Sanati NezhadBioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada. amir.sanatinezhad@ucalgary.ca.

Funding

Alberta Innovates 10032191CIHR 10036386Mitacs 10037451
6 · The paper itself

Abstract

The reproducibility of ultrasensitive biosensors is vital for clinical research, scalable manufacturing, commercialization, and reliable clinical decision-making, as batch-to-batch variations introduce significant uncertainty. However, most biosensors lack robust quality control (QC) measures. This study introduces an innovative QC strategy to produce highly reproducible molecularly imprinted polymer (MIP) biosensors by leveraging real-time data from the electrofabrication process. Prussian Blue nanoparticles (PB NPs) embedded within the MIP structure enable precise monitoring of surface properties, conductivity, MIP film thickness, and template extraction efficiency. The QC strategy utilizes variations in the current intensity of PB NPs during fabrication to implement real-time, non-destructive QC protocols at critical fabrication stages, minimizing measurement variability and ensuring consistency. This approach was validated by fabricating MIP biosensors for detecting agmatine metabolite and glial fibrillary acidic protein (GFAP) in phosphate-buffered saline (PBS). The QC strategy reduced relative standard deviation (RSD) by 79% for agmatine (RSD = 2.05% QC, RSD = 9.68% control) and 87% for GFAP (RSD = 1.44% QC, RSD = 11.67% control). Moreover, quality-controlled biosensors achieved success rates of 45% for agmatine and 36% for GFAP detection, significantly outperforming bare screen-printed electrodes. This work marks a significant advancement in biosensor development by integrating robust QC protocols directly into the fabrication process. By embedding PB NPs and monitoring electrochemical signals in real-time, this strategy delivers an unprecedented level of reproducibility, scalability, and reliability for MIP biosensors, addressing critical challenges in point-of-care diagnostics and commercial applications.

Indexed as

Biosensing TechniquesFerrocyanidesMolecular ImprintingMolecularly Imprinted PolymersNanoparticlesHumansPolymersReproducibility of Resultsferric ferrocyanideFerrocyanidesMolecularly Imprinted PolymersPolymersElectrochemical biosensorElectrodepositionMolecularly imprinted polymersPrussian blue nanoparticlesQuality control

Identifiers

PMID40087363
PMCPMC11909151

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.