SynthesisChinese journal of traumatology = Zhonghua chuang shang za zhi2025
Comparison of hook plates vs. locking plates for Neer type IIB fractures of lateral end clavicle: A systematic review.
Synthesis in Chinese journal of traumatology = Zhonghua chuang shang za zhi, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Hook plate versus locking plate fixation in lateral clavicle fractures: operative efficiency and cumulative surgical burden in a propensity score-matched cohort study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Treatment Strategies for Distal Clavicle Fractures: A Narrative Review.Orthopedic research and reviews · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSurgical management of the lateral end of clavicle fractures has been a challenge for orthopedic surgeons considering the high rate of non-union. There has been no right and wrong answer to these types of fractures and many methods discussed in the literature, but the 2 most used bony procedures are hook plate and locking plate with or without the use of supplementary soft tissue procedures. The available evidence, in this case, is scarce with questionable reliability. The idea of this systemic review is to promote evidence-based practice when choosing between the 2 implants for this fracture. This study aims to review the results by performing a systemic review of the literature comparing the results of locking plate vs. hook plate for the lateral end of clavicle fracture fixation with an emphasis on outcome and associated complications.
methodsA search of the literature was made with the keyword "clavicle" in PubMed/Ovid Medline/Embase and University of Edinburgh online library "discover Ed". A total of 4063 articles were identified including case series (with at least 3 cases) and review articles focusing on locking plate alone, comparisons of locking plate and hook plate, or hook plate alone. Articles were excluded if they were not published in English, focused on pediatric studies, or consisted only of book chapters. Studies examining tension band wiring, soft tissue procedures for fracture fixation, arthroscopic-assisted procedures, additional soft tissue procedures along with plate fixation, and fracture dislocation of the lateral end of the clavicle were also excluded. The search was then narrowed down to 21 articles after consideration of inclusion and exclusion criteria. A detailed review of the surgical methodology further excluded additional soft tissue procedures, resulting in a final selection of 15 studies. The quality of the studies was assessed using the Modified Coleman Score by the authors.
resultsA total of 15 studies related to Neer type II fracture met the inclusion criteria. However, 2 other studies also included type V fracture as well. The mean age of patients in these studies was 32 years. The mean follow-up period was 24.3 months (ranging from 6 to 65 months). The time of radiological union was documented from 2 to 4.5 months. Constant and disabilities of arm, shoulder, and hand scores were most used as the criteria for patient outcomes. The size of the lateral fragment that can accommodate/provide bicortical fracture was documented in only 3 studies. The mean incidence of removal of hook plate was 86.9%. In contrast, the mean incidence of removal of locking plate was 27.0%. Superficial wound infection was documented in 5 studies and deep wound infection was seen in 1 study. The mean union rate for hook plate was 97.0% compared to 100% for locking plate. Complications associated with hook plate have been documented in 11 studies. The most commonly reported incidence of complication was acromial osteolysis. The quality of studies was assessed using modified Coleman score. Other than 2 studies that were considered for the study that met the "fair" standard all of them were considered "poor" based on the modified Coleman score.
conclusionBoth hook plate and locking plate provide acceptable operative treatment options for the lateral end of clavicle fracture. However, a consideration of surgeons' experience, the likelihood of a second operation, and the size of the lateral fragment should be considered when choosing between the 2 types of implants.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.