Evidence map›Paper›PMID 40083180›Full record

ReviewClinical transplantation and research2025

Exploring the utility of near-infrared spectroscopy in liver transplantation: insights and challenges.

Ravshan Ibadov, Konstantin Semash, Mirshavkat Akbarov, Timur Dzhanbekov, Oybek Omonov, Azimjon Usmonov, Sardor Ibragimov

Abstract readReview
In one paragraph

Review in Clinical transplantation and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ravshan IbadovDepartment of Anesthesiology, Resuscitation, and Intensive Care, Republican Specialized Scientific and Practical Medical Center for Surgery named after Academician V. Vakhidov, Tashkent, Uzbekistan.ORCID https://orcid.org/0000-0002-0992-0802
Konstantin SemashDepartment of Minimally Invasive Pediatric Surgery, National Children's Medical Center, Tashkent, Uzbekistan.ORCID https://orcid.org/0000-0001-5830-5235
Mirshavkat AkbarovDepartment of Hepatobiliary Surgery and Liver Transplantation, Republican Specialized Scientific and Practical Medical Center for Surgery named after Academician V. Vakhidov, Tashkent, Uzbekistan.ORCID https://orcid.org/0000-0002-7793-1810
Timur DzhanbekovDepartment of Minimally Invasive Pediatric Surgery, National Children's Medical Center, Tashkent, Uzbekistan.ORCID https://orcid.org/0000-0002-8857-947X
Oybek OmonovDepartment of Endocrine Surgery, Republican Specialized Scientific and Practical Medical Center of Endocrinology named after Academician Y. Kh. Turakulov, Tashkent, Uzbekistan.ORCID https://orcid.org/0000-0002-8182-6052
Azimjon UsmonovDepartment of Hepatobiliary Surgery and Liver Transplantation, Republican Specialized Scientific and Practical Medical Center for Surgery named after Academician V. Vakhidov, Tashkent, Uzbekistan.ORCID https://orcid.org/0009-0006-1179-6835
Sardor IbragimovDepartment of Anesthesiology, Resuscitation, and Intensive Care, Republican Specialized Scientific and Practical Medical Center for Surgery named after Academician V. Vakhidov, Tashkent, Uzbekistan.ORCID https://orcid.org/0000-0003-2876-411X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Maintaining adequate tissue perfusion and oxygen delivery to the transplanted liver is critical for positive patient outcomes. Near-infrared spectroscopy (NIRS) has emerged as a promising tool for evaluating graft function in liver transplantation, particularly in assessing tissue perfusion. This review consolidates current knowledge regarding the application of NIRS in liver transplantation, highlighting its potential for noninvasive, continuous monitoring of liver perfusion and early detection of hemodynamic disturbances. Initial studies demonstrate the sensitivity of NIRS in evaluating liver oxygenation, with significant correlations observed between NIRS readings and biochemical markers of liver function. However, the effectiveness of NIRS can be influenced by factors such as subcutaneous fat thickness and patient positioning. Recent advancements also suggest that NIRS may assist in predicting graft fibrosis and other longterm complications. More extensive studies are required to establish standardized protocols and validate the clinical utility of NIRS in liver transplantation.

Indexed as

Liver transplantationNear-infrared spectroscopyOxygenationRegional blood flow

Identifiers

PMID40083180
PMCPMC12203269

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.