ArticleBMC oral health2025
The influence of microplate spacing on mandibular ramus fracture fixation stability: a biomechanical finite element analysis.
Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo investigate the effect of different microplate spacing on the relative displacement of the fractured mandibular ramus during mastication after using double microplates for fixation, using finite element analysis. This study aims to provide a theoretical basis for clinical design of the distance between two microplates.
methodsFinite element models of the mandible, teeth, periodontal membrane, and microplates (Johnson & Johnson, thickness 1 mm) were established. A fracture line was set on the mandibular ramus from the sigmoid notch to the angle of the mandible, corresponding to the type I fracture line of the mandibular ramus. The experiment designed the distance between two microplates into 22 groups, with 2 mm as the initial distance and an increase of 1 mm per step, gradually increasing the distance between the two microplates to 23 mm. Friction contact was set between the two fracture fragments, and the bilateral condyles were fixed. A bite force of 230 N was applied to the bilateral first molars, and the relative displacement between the two fracture fragments under this load was calculated.
resultsThe results showed that as the distance between the microplates increased, the relative displacement gradually decreased, from 0.46751 mm at a distance of 2 mm to 0.105789 mm at a distance of 23 mm. The relative displacement at a distance of 20 mm was 0.147448 mm, which was below the clinical critical value of 0.15 mm for the direct healing.
conclusionAfter using double microplates for fixation of mandibular ramus fractures, the stability of the fracture fixation during mastication increases with the increase in the distance between the two microplates. At a distance of 20 mm, While theoretically capable of achieving the criteria for direct healing, further clinical validation remains necessary.