Evidence map›Paper›PMID 40081751›Full record

ArticleExperimental eye research2025

Monitoring mutant myocilin secretion and localization in trabecular meshwork cell cultures using a protein complementation-based luminescence assay.

Hannah A Youngblood, Ethan F Harris, Kaylee P Lankford, Victoria Garfinkel, John D Hulleman, Raquel L Lieberman

Abstract read
In one paragraph

Article in Experimental eye research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Hannah A YoungbloodSchool of Chemistry & Biochemistry, Georgia Institute of Technology, USA.
Ethan F HarrisSchool of Chemistry & Biochemistry, Georgia Institute of Technology, USA.
Kaylee P LankfordDepartment of Ophthalmology, University of Texas Southwestern Medical Center, USA.
Victoria GarfinkelDepartment of Ophthalmology, University of Texas Southwestern Medical Center, USA.
John D HullemanDepartment of Ophthalmology, University of Texas Southwestern Medical Center, USA; Department of Ophthalmology and Visual Neurosciences, University of Minnesota, USA. Electronic address: hulleman@umn.edu.
Raquel L LiebermanSchool of Chemistry & Biochemistry, Georgia Institute of Technology, USA. Electronic address: Raquel.lieberman@chemistry.gatech.edu.

Funding

Request for Supplement to Promote Diversity in Health Related ResearchR01EY021205 · NEI · GEORGIA INSTITUTE OF TECHNOLOGY · PI Raquel L Lieberman · 2011 to 2026
$6.8M
VIsion Science Training in AtlantaT32EY007092 · NEI · EMORY UNIVERSITY · PI Machelle T. Pardue · 1985 to 2026
$4.6M
T35 NEI Medical Student Summer Research TrainingT35EY026510 · NEI · UT SOUTHWESTERN MEDICAL CENTER · PI Benjamin Franklin Chong, DANIELLE M. ROBERTSON · 2018 to 2026
$99k
NEI NIH HHS R01 EY021205NEI NIH HHS T32 EY007092NEI NIH HHS T35 EY026510
6 · The paper itself

Abstract

Approximately 2-4 % of adult onset and 10 % of juvenile onset cases of primary open angle glaucoma can be attributed to non-synonymous coding mutations in MYOC. One of the key characteristics of a pathogenic MYOC mutant is the inability of the resulting protein to be secreted from trabecular meshwork cells. Instead, pathogenic myocilin variants accumulate in the endoplasmic reticulum. Typically, localization of MYOC mutants is compared to wild-type myocilin in cellular secretion assays that use immunoblot to detect myocilin in extracellular media, alongside intracellular soluble and insoluble (aggregated) fractions. Here, we implement a new method that utilizes a complement-based luminescence method in which an 11-residue HiBiT tag is appended to myocilin and complements a truncated nanoluciferase. The method allows for highly sensitive luminescence detection and does not require immunoblot. We tested non-synonymous coding variants T377R, D384G, D395ins, C433Y, T455K, and L486F, in an established immortalized trabecular meshwork cell line. Secretion was tested in 96-well plate format, revealing poor secretion for these mutants compared to wild-type myocilin. For assays conducted in 6-well plates, myocilin mutants were accumulated in intracellular fractions. HiBiT luminescence signals correlated well with immunofluorescence as well as immunoblot but is more sensitive than the latter. Overall, our study demonstrates that complement-based detection of mutant myocilin using luminescence allows for facile and sensitive detection of myocilin localization and has confirmed secretion defects for six variants.

Indexed as

Cytoskeletal ProteinsEye ProteinsGlaucoma, Open-AngleGlycoproteinsMutationTrabecular MeshworkCells, CulturedHumansLuminescent MeasurementsMyocilinCytoskeletal ProteinsEye ProteinsGlycoproteinsMyocilinCellular traffickingGlaucomaImmunoblotImmunofluorescenceLuminescenceMisfoldingMyocilinSecretion

Identifiers

PMID40081751
PMCPMC12058393

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.