Evidence map›Paper›PMID 40080258›Full record

ArticlePhysical and engineering sciences in medicine2025

Investigation of the tissue equivalence of typical 3D-printing materials for application in internal dosimetry using monte carlo simulations.

Ayse Karadeniz-Yildirim, Handan Tanyildizi-Kokkulunk

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ayse Karadeniz-YildirimOpticianry Program, Istanbul Aydın University, Florya, Bakirkoy, Istanbul, 34295, Turkey.ORCID http://orcid.org/0000-0001-9301-4775
Handan Tanyildizi-KokkulunkRadiotherapy Program, Altınbaş University, Kartaltepe Dist, Bakirkoy, Istanbul, 34147, Turkey. handan.kokkulunk@altinbas.edu.tr.ORCID http://orcid.org/0000-0001-5231-2768

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluates the dosimetric accuracy of PLA and ABS 3D-printed phantoms compared to real tissues using Monte Carlo simulations in radionuclide therapy. MATERIALS AND

methodsA phantom representing average liver and lung volumes, with a 10 mm tumor mimic in the liver, was simulated for radioembolization using 1 mCi Tc-99 m and 1 mCi Y-90. The dose distribution (DD) was compared across PLA, ABS, and real organ densities.

resultsFor Tc-99 m, PLA showed a + 5.6% DD difference in the liver, and ABS showed - 35.3% and - 40.9% differences in the lungs. For Y-90, PLA had a + 1.7% DD difference in the liver, while ABS showed - 34.2% and - 34.9% differences in the lungs.

conclusionIn MC simulation, PLA is suitable for representing high-density tissues, while ABS is appropriate for simulating moderately low-density tissues.

Indexed as

Computer SimulationMonte Carlo MethodPrinting, Three-DimensionalRadiometryHumansLiverLungPhantoms, ImagingABSInternal dosimetryNuclear medicinePhantomPLA

Identifiers

PMID40080258
PMCPMC12209393

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.