Evidence map›Paper›PMID 40080057›Full record

ArticlePacing and clinical electrophysiology : PACE2025

Long-Term Follow-Up of the S-ICD: A 10-Years Follow-Up Study of a Large Single Center Cohort.

Gerrit Frommeyer, Florian Reinke, Benjamin Rath, Julian Wolfes, Kevin Willy, Felix K Wegner, Julia Köbe, Lars Eckardt

Abstract read
In one paragraph

Article in Pacing and clinical electrophysiology : PACE, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. The SIDECAR 2.0 (S-ICD registry in European paediatric and young adult patients with congenital heart defects 2.0): an analysis of European S-ICD clinical practice and its evolution in paediatric patients.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Observational
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gerrit FrommeyerClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.ORCID 0000-0002-1431-9886
Florian ReinkeClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Benjamin RathClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Julian WolfesClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Kevin WillyClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Felix K WegnerClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Julia KöbeClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.
Lars EckardtClinic for Cardiology II: Electrophysiology, University Hospital Münster, Münster, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe subcutaneous implantable defibrillator (S-ICD) is an alternative to transvenous implantable defibrillators. The present analysis presents real-world data from patients with S-ICD and a follow-up duration of 10 years or more. METHODS AND

resultsBetween July 2010 and November 2013 76 S-ICD systems were implanted. After a follow-up duration of 10 years, data from 67 patients (88.1%) was available. Mean follow-up duration was 10.7 ± 1.3 years. Forty-seven patients (70.2%) were still alive with active S-ICD therapy. Eight patients (11.9%) died during follow-up. In eight patients (11.9%), conversion to a transvenous ICD system was necessary. This was either due to heart failure with indication for biventricular pacing (n = 2), bradycardia (n = 3), oversensing that could not be solved (n = 2), or pocket infection (n = 1). In four patients (6%), the S-ICD system was explanted without replacement for individual reasons. Sixteen patients already underwent two generator replacements, while one generator replacement was performed in the rest of the cohort. Therefore, generator longevity was documented to be within the predicted values. In 10 patients (14.9%), appropriate therapy delivery for ventricular arrhythmias was delivered. In 12 patients (17.9%), inappropriate shock delivery due to oversensing occurred. Of note, this could be resolved in all but two patients. Furthermore, the majority of these episodes occurred in the early years before the implementation of the Smart Pass algorithm.

conclusionS-ICD therapy can be successfully maintained over a long time. Incidence of oversensing significantly decreased with the implementation of novel algorithms and the new S-ICD generation. However, the present data also points out that in selected individuals conversion to transvenous systems is required.

Indexed as

Defibrillators, ImplantableHeart FailureAgedCohort StudiesFemaleFollow-Up StudiesHumansMaleMiddle AgedTreatment OutcomeS‐ICDsudden cardidac death

Identifiers

PMID40080057
PMCPMC11969912

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.