ArticleMaterials (Basel, Switzerland)2025
A Micro-Nodal Tungsten-Rhenium Thin-Film Thermocouple Based on Electrohydrodynamic Printing.
Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Flexible NiCr-NiSi Thin-Film Thermocouple Sensor for Temperature Monitoring of Telecommunication Equipment.Micromachines · 2026Article
- Deep Learning-Based Calibration of a Multi-Point Thin-Film Thermocouple Array for Temperature Field Measurement.Sensors (Basel, Switzerland) · 2026Article
- A Temperature Measurement and System Identification Method for Confined Cavity Explosions Based on an Improved Type C Thermocouple Sensor.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
High-temperature thin-film thermocouples (TFTCs) have gained significant attention in the aerospace and energy industries due to their compact size and millisecond response time. Although previous studies have reduced the size of TFTCs to the millimeter scale, the heat flow field has continued to limit temperature measurement accuracy. To address this issue, this study used an electrohydrodynamic printing process to fabricate tungsten-rhenium TFTCs with a thickness at the micrometer scale. In the static test, the tungsten-rhenium TFTCs showed good performance with a measurement accuracy better than 1.2%, repeatability better than 0.99%, and a drift rate of 0.72%/h. In dynamic tests, the response time was 1.2 ms. Additionally, during flame gun heating tests, the response time and temperature measurement accuracy exceeded those of the standard thermocouple.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.