Evidence map›Paper›PMID 40075159›Full record

ArticleScientific reports2025

A new method of accurate pedicle screw navigation.

Daniel Suter, Aidana Massalimova, Christoph Johannes Laux, Laura Leoty, José Miguel Spirig, Florentin Liebmann, Fabio Carrillo, Philipp Fürnstahl, Mazda Farshad

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Daniel SuterResearch in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland. dapesu@bluewin.ch.ORCID http://orcid.org/0000-0003-1916-5115
Aidana MassalimovaResearch in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.ORCID http://orcid.org/0000-0002-6203-1270
Christoph Johannes LauxSpine Division, Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.ORCID http://orcid.org/0000-0002-5446-3057
Laura LeotyResearch in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.
José Miguel SpirigSpine Division, Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.
Florentin LiebmannResearch in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.ORCID http://orcid.org/0000-0001-7722-2267
Fabio CarrilloResearch in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.ORCID http://orcid.org/0000-0002-0942-0277
Philipp FürnstahlResearch in Orthopedic Computer Science, University Hospital Balgrist, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.ORCID http://orcid.org/0000-0001-6484-6206
Mazda FarshadSpine Division, Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, Zurich, 8008, Switzerland.ORCID http://orcid.org/0000-0002-7190-1127

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One of the most established approaches to navigate pedicle screws is the planning and alignment (PA) method. Thereby a trajectory and associated entry point (EP) is planned and navigated after referencing to patient anatomy. However, deviations from the planned EP potentially lead to an altered screw position. The aim of this study was to investigate the influence of these EP deviations and to examine possible alternative methods. The merits of two new points of reference (screw tip point STP and midpoint MP) were therefore analyzed. STP represents the point on the optimal screw tip, MP the point at the center/midportion of the pedicle at its narrowest portion. The adapted screw trajectory was defined as the directional vector from any chosen EP to the STP or MP. First, computer simulations were used to evaluate the performance of these new approaches. Subsequently, the navigation technique yielding more acceptable screws in case of an EP deviation was analyzed on phantom-sawbone models. Both new methods showed a significantly larger number of possible screw trajectories in the simulations (p < 0.01). Even with a deliberate deviation of 4.5 mm (IQR 3.3) from the optimal EP, a perforation-free screw diameter of 4.9 mm (IQR 5.7 mm) could be achieved using the new navigation techniques. The simulated perforations were mainly located laterally with a median of 8.45 mm (IQR 3.95) distance to the medial pedicle wall. The PA method seems to be susceptible to EP deviations. The STP and MP methods are possible improvement mechanisms to overcome this disadvantage.

Indexed as

Pedicle ScrewsSpinal FusionSurgery, Computer-AssistedComputer SimulationHumansPhantoms, ImagingAugmented realityComputer assisted surgeryPedicle screw accuracyPedicle screw navigationSpinal surgery.

Identifiers

PMID40075159
PMCPMC11904219

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.