Does Leak Matter? A Novel Dynamic Leak Model to Simulate Leak for Performance Testing of Manual Neonatal Resuscitation Devices. A Bench Study.

Stephanie Morakeas, Mark Brian Tracy, Murray Hinder, Viktoria Gruber, Alistair McEwan, Thomas Drevhammar

Abstract read
In one paragraph

Article in Pediatric pulmonology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Stephanie MorakeasNeonatal Intensive Care Unit, Westmead Hospital, Sydney, New South Wales, Australia.ORCID http://orcid.org/0000-0001-9663-0864
Mark Brian TracyNeonatal Intensive Care Unit, Westmead Hospital, Sydney, New South Wales, Australia.
Murray HinderNeonatal Intensive Care Unit, Westmead Hospital, Sydney, New South Wales, Australia.ORCID http://orcid.org/0000-0002-9179-316X
Viktoria GruberDepartment of Paediatrics and Adolescent Medicine, Division of Neonatology, Medical University Graz, Graz, Austria.
Alistair McEwanFaculty of Engineering and Information Technologies, BMET Institute, The University of Sydney, Sydney, New South Wales, Australia.
Thomas DrevhammarDepartment of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.ORCID http://orcid.org/0000-0002-4038-2221

Funding

We acknowledge funding support from a PhD Research Grant awarded by Cerebral Palsy Alliance (PHD04123). This research is also supported by an Australian Government Research Training Program (RTP) Scholarship (N/A) awarded to Stephanie Morakeas.
6 · The paper itself

Abstract

introductionNewborn resuscitation is commonly performed in the presence of face mask leak. Leak is highly variable, pressure-dependent and often unrecognized. The effectiveness of resuscitation devices to deliver adequate inflations in the presence of leak is unknown. Bench models simulating continuous leak have the disadvantage of not accurately reflecting leak occurring during clinical resuscitation. A dynamic leak model based on pressure-release valves was thus developed.

methodsThis study investigates self-inflating bag (SIB) and T-piece resuscitator (TPR) ventilation performance in the presence of dynamic (DLM) compared to continuous (CLM) leak models in a bench study. Five predefined leak levels were tested for each leak model (0%-87%). Resuscitation devices were connected to a test lung (compliance 0.6 mL/cmH

resultsThree thousand six hundred inflations were analyzed. DLM showed a decrease in actual tidal volumes from 0%-87% leak with tidal volume differences (SIB 4.8 mL, TPR 2.9 mL), contrasting to minimal change for CLM (SIB -0.6 mL, TPR 0.3 mL). CLM demonstrated larger differences between patient interface and actual leak. The absolute difference at 60 inflations/min at 87% leak were SIB 37.5%, TPR 18.2% for CLM compared to SIB 4.6%, TPR 1.4% for DLM.

conclusionsCLM may underestimate the impact of resuscitation device performance with poor correlation between patient interface and actual delivered volume. DLM demonstrates several advantages with a more accurate representation of face mask leak and will prove useful in modeling all systems delivering PPV.

Indexed as

Respiration, ArtificialResuscitationEquipment DesignEquipment FailureHumansInfant, NewbornMasksPositive-Pressure RespirationTidal Volumeleakmask leakneonatal resuscitationpositive pressure ventilation