Evidence map›Paper›PMID 40071018›Full record

ArticleIndian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India2025

Round Window Membrane Visibility and its Implications in Cochlear Implant Surgery.

Kanchan Tadke, Harshali Girde, Labhashree Bhosey, Aniket Daund, Sai Musty

Abstract read
In one paragraph

Article in Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kanchan TadkeDepartment of ENT, Government Medical College and Hospital, Nagpur, 440003 India.ORCID 0009-0002-6576-6210
Harshali GirdeDepartment of ENT, Government Medical College and Hospital, Nagpur, 440003 India.
Labhashree BhoseyDepartment of ENT, Government Medical College and Hospital, Nagpur, 440003 India.
Aniket DaundDepartment of ENT, Government Medical College and Hospital, Nagpur, 440003 India.
Sai MustyDepartment of ENT, Government Medical College and Hospital, Nagpur, 440003 India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With increasing number of patients with residual hearing being implanted, there is a renewed interest in round window (RW) as the preferred route for electrode insertion to reduce intracochlear trauma. The degree of round window membrane (RWM) visibility and its orientation might hamper the accessibility of RW for electrode insertion. This study is an attempt to identify the various factors affecting the accessibility of RW for electrode insertion. 30 children fulfilling the CI candidacy criteria were recruited for the study. All the surgeries were performed by the standard posterior tympanotomy technique. Round window membrane (RWM) visibility was graded into four types from grade I to grade IV. The membrane visibility was assessed prior to niche drilling. Grade III RW was the most common type. RW insertion could be achieved in 66.7% cases, while extended RW was performed in 33.3% cases. Bony cochleostomy was not required in any of the cases. There was no significant association between grade of RWM visibility and the route of electrode insertion. RW insertion could be achieved in most cases with normal cochlear anatomy. We observed that the grades of RWM visibility did not affect the route of electrode insertion. RW insertion can be performed in a manner that is potentially less traumatic by following the surgical steps meticulously. Both RWM visualization and insertion angle can be improved with careful bone removal in RW niche region making the round window a viable option, when minimizing insertion trauma in patients.

Indexed as

Cochlear implant surgeryElectrode insertion routeRound window membrane visibility

Identifiers

PMID40071018
PMCPMC11890852

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.