Evidence map›Paper›PMID 40070802›Full record

ArticleEuropean heart journal. Case reports2025

Acurate Neo2 for valve-in-valve treatment of degenerated 3F Enable sutureless bioprosthetic valve in nonagenarian patient: a case report.

Andres Agustin Vecchia, Giuseppe Migliaro, Paolo Cioffi, Dario Calderone, Giuseppe Verolino

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Andres Agustin VecchiaCardiac Cath Lab, Città di Alessandria Institute, Via Moccagatta 30, 15121 Alessandria, Italy.ORCID https://orcid.org/0000-0002-1295-3322
Giuseppe MigliaroUnit of Cardiovascular Science, Campus Bio-Medico University of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy.ORCID https://orcid.org/0009-0009-5432-1575
Paolo CioffiCardiac Cath Lab, Città di Alessandria Institute, Via Moccagatta 30, 15121 Alessandria, Italy.
Dario CalderoneInvasive Cardiology-IRCCS Istituto Auxologico Italiano, San Luca Hospital, Piazzale Brescia 20, 20148 Milan, Italy.ORCID https://orcid.org/0000-0002-9445-4294
Giuseppe VerolinoInvasive Cardiology-IRCCS Istituto Auxologico Italiano, San Luca Hospital, Piazzale Brescia 20, 20148 Milan, Italy.ORCID https://orcid.org/0000-0002-2369-109X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Sutureless bioprosthetic valves (SBVs) are engineered to enable a less invasive surgical valve replacement procedure in patients at high surgical risk. Valve degeneration is a relatively common occurrence across all types of surgical valves, including SBVs. Valve-in-valve (ViV) procedures are increasingly becoming the preferred treatment for many cases of valve degeneration due to their minimally invasive nature and favourable long-term outcomes. However, the specific structural characteristics of SBVs present challenges for ViV procedures, and the evidence on this subject remains limited. Case summary: A 91-year-old man was admitted to our hospital presenting with dyspnoea due to severe aortic regurgitation in a degenerated 3F Enable sutureless valve. Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) was successfully performed using a self-expanding Acurate Neo2 valve, yielding good haemodynamic results without overt interaction between the prosthesis. A 6-month follow-up echocardiogram confirmed excellent valve performance. Discussion: ViV-TAVI is a well-established treatment for bioprosthetic valve failure in high-risk patients. However, sutureless valve degeneration presents a challenging scenario for ViV procedures, with only a limited number of cases performed using the Acurate platform. In this case, we demonstrated the technical feasibility of ViV using the Acurate system in a less explored surgical sutureless bioprosthesis.

Indexed as

3F EnableAortic regurgitationCase reportSelf-expandable valveStructural valve deteriorationSurgical sutureless valveValve-in-valve TAVI

Identifiers

PMID40070802
PMCPMC11895507

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.