ArticleMikrochimica acta2025
Sulfonated reduced graphene oxide-doped polypyrrole film prepared by in situ electropolymerization and coating in fabrication of ammonia gas sensor for exhaled breath analysis of patients with kidney failure.
Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Recent Advances in Polypyrrole-Based Functional Coatings: Surface Protection and Emerging Applications.Materials (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Detection of the level of ammonia gas in exhaled breath provides non-invasive and fast diagnosis of kidney failure. Here, we fabricated room temperature and sensitive chemiresistive ammonia gas sensor by in situ electropolymerization and deposition of polypyrrole/sulfonated graphene oxide (PPy/SRGO) on/between gold interdigitated electrodes (Au-IDEs). The prepared sensors were characterized by using field emission scanning electron microscopy (FESEM) and Fourier transform infrared (FT-IR). The fabricated ammonia gas sensor was tested at different operating temperatures (26-50°C) and we selected room temperature for simplifying operation (26°C). At this temperature, the sensor showed two linear ranges of 5-40 ppb (R
Indexed as
Identifiers
40069503What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.