ArticleJournal of applied clinical medical physics2025

Commissioning a standalone adaptive radiotherapy linac in a multi-vendor environment.

Sven Olberg, David M McClatchy, Colleen Foote, Susu Yan, Jennifer Pursley

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sven OlbergDivision of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts, USA.
David M McClatchyDivision of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts, USA.
Colleen FooteDivision of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts, USA.
Susu YanDivision of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts, USA.
Jennifer PursleyDivision of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0002-0531-6798

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current radiotherapy machines intended to perform streamlined online adaptive therapy are designed to be standalone, which makes it challenging to integrate them with the rest of the clinic. This work describes the installation of a standalone CT-guided online adaptive system, the Varian Ethos, in a busy clinic utilizing products from multiple vendors, including RayStation as the treatment planning system (TPS) and MOSAIQ as the oncology information system (OIS). The aim was to develop solutions that minimized workload increases for staff using redundant systems and to implement this new technology safely, with no increase in safety reports resulting from its integration into the clinic. The Ethos was delivered with a pre-configured beam model, and a separate Ethos beam model was developed in RayStation 10A. Non-adaptive treatments were planned in RayStation and transferred to Ethos for delivery. Although MOSAIQ 2.64 could not communicate with the Ethos, a machine characterization file was developed to allow manual recording of the treatment fields in MOSAIQ. Online adaptive therapy was performed using the Ethos TPS and OIS with documentation in MOSAIQ. Although dose calculations of the same plans differed by 1%-2% in the pelvis in RayStation compared to the Ethos TPS, dose computed in both systems passed measurement-based QA, end-to-end testing, and clinical trial credentialing, so both systems were commissioned for clinical use. RayStation plans were successfully modified for delivery on Ethos, and at go-live, all non-adaptive planning was performed in RayStation and adaptive planning in Ethos. Ethos treatments were documented in MOSIAQ, which remained the OIS of record for all patients. Monitoring of error reports indicated some unique failure modes to the new technology, but the overall number of safety reports remained comparable to other systems. In conclusion, Ethos was successfully deployed for both non-adaptive and online adaptive therapy in a multi-vendor environment.

Indexed as

NeoplasmsParticle AcceleratorsRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosageTomography, X-Ray Computedadaptive therapycommissioningmulti‐vendor environment

Identifiers

PMID40065470
PMCPMC11969105

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.