ArticleEye (London, England)2025
Implantable collamer lens sizing optimization based on the anterion AS-OCT biometric parameters.
Article in Eye (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo develop regression formulas for determining optimal Implantable Collamer Lens (ICL) size based on Anterion AS-OCT (anterior segment optical coherence tomography) biometric data.
methodsIn this retrospective interventional case series, 89 patients were included in the development phase and 57 patients were included in the (internal) validation phase. The study developed the SN (Salouti-Nowroozzadeh) formula, a multiple step-wise linear regression model, incorporating anterior chamber width (ACW), lens thickness, and anterior chamber volume (ACV) as predictors, to determine optimal ICL size (R-square=0.602). Another formula predicted ICL vault using a cubic non-linear model and the difference (Delta) between implanted and predicted ICL size as an explanatory variable (R-square = 0.599). Logistic regression determined the probability of achieving optimal vault or acceptable vault post-surgery. We also present findings from 73 consecutive prospective cases from a separate dataset, where the ICL was determined using the SN formula (external validation).
resultsDelta was the sole independent factor predicting postoperative ICL vault. A ∆ value of 0.3 mm corresponded to a 65% probability of achieving optimal vault, while a ∆ value of 0.15 resulted in an 80% probability. The SN formula matched with the STAAR nomogram in 69.9% of cases (79/113). Compared to the STAAR formula, the SN formula recommended a larger size in 10 eyes (8.8%) and a smaller size in 24 (21.2%). The 95% LoA for SN-predicted and actual ICL vault were (-339 to 518) µm. The mean absolute error was 191 µm (SD,139), and 72 eyes (63.7%) had a difference of ≤200 µm. The external validation analysis confirmed the primary findings.
conclusionsThe developed regression formula provided acceptable predictions for proper ICL sizing in our patients. However, its performance may vary across different populations or measurement devices. This study also highlights the need for smaller increments of ICL sizes to improve postoperative outcomes with any given formula.