Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation.

Fang Liu, Yijia Xu, Yuhao Ye, Zhe Zhang, Lingling Niu, Peijun Yao, Xiaoying Wang, Xingtao Zhou, Jing Zhao

Abstract read
In one paragraph

Article in Clinical optometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fang Liu *Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Yijia Xu *Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Yuhao YeDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Zhe ZhangDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Lingling NiuDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Peijun YaoDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Xiaoying WangDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.
Xingtao ZhouDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.ORCID 0000-0002-3465-1579
Jing ZhaoDepartment of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To compare vault measurement using Pentacam (Oculus, Germany) and two optical coherence tomography (OCT) instruments, Casia2 (Tomey Corporation, Japan) and RTVue (Optovue Inc. USA). Methods: This comparative study recruited 95 eyes of 50 patients (mean age: 28.40±4.51, male/female 15/35) who underwent implantable collamer lens (ICL) implantation for myopia correction. All patients underwent a series of ophthalmic examinations at 3 and 6 months postoperatively, and the vault was measured using three instruments in the same order at both follow-ups. Intraclass coefficients (ICC) and Bland-Altman plots were used to analyze intra-equipment reproducibility and agreement between two instruments. A multivariate regression model was used to analyze the factors influencing the vault differences between the devices. Results: The ICC values for intra-observer and inter-observer reproducibility of each piece of equipment were above 0.9. The ICC values and mean differences of vault measurement of Casia2 vs Pentacam, Casia2 vs RTVue, and RTVue vs Pentacam were 0.763 and 139.81 μm, 0.960 and -17.18 μm, 0.739 and 151.86 μm, respectively. An average of 96.2% of the points fell within the limit of agreement in the Bland-Altman plots. No difference was found in the inter-device agreement between the 3- and 6-month vaults. The difference in pupil diameter, anterior chamber depth, and anterior chamber angle could influence the vault difference between the Pentacam and the two OCT instruments. Conclusion: All three instruments demonstrated good intra-equipment reproducibility. Casia2 and RTVue showed excellent agreement in the vault measurements. The Pentacam's vault readings were significantly lower than those measured by Casia2 and RTVue; therefore, their vault measurements were not interchangeable.