Evidence map›Paper›PMID 40061096›Full record

ArticleRadiologia brasileira

Improving osteoarticular characterization in magnetic resonance imaging: the role of simulated computed tomography sequences.

Gabriel Brito-Barbosa, Felipe Bortoloni Pires Correa, Leonor Garbin Savarese, Mateus Andrade Hernandes, Paulo Moraes Agnollitto, Marcelo Novelino Simão, Marcello Henrique Nogueira-Barbosa

Abstract read
In one paragraph

Article in Radiologia brasileira. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gabriel Brito-BarbosaDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0009-0004-0391-7989
Felipe Bortoloni Pires CorreaDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0009-0009-1887-4893
Leonor Garbin SavareseDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0000-0002-1372-9162
Mateus Andrade HernandesDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0000-0002-2244-5532
Paulo Moraes AgnollittoDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0000-0003-1818-3266
Marcelo Novelino SimãoDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0000-0002-2164-1910
Marcello Henrique Nogueira-BarbosaDepartment of Medical Imaging, Hematology, and Clinical Oncology, Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (FMRP-USP), Ribeirão Preto, SP, Brazil.ORCID 0000-0002-7436-5315

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Increasing tissue contrast for bone assessment on magnetic resonance imaging has been the aim of several recent studies, and various techniques have been proposed for that purpose, including ultrashort echo time sequences, zero echo time sequences, and gradient echo sequences in various acquisition forms. In this article, we discuss the fast field echo resembling a computed tomography using restricted echo-spacing (FRACTURE) sequence, which we have started to use routinely in our practice. The FRACTURE sequences are based on the acquisition of gradient echo sequences with different echo times and specific postprocessing. Gradient echo sequences are widely available on magnetic resonance imaging scanners, which is an advantage for the use of a FRACTURE sequence. However, being more susceptible to metal artifacts, a FRACTURE sequence is of limited utility in patients with metallic implants or medical devices. The aim of this article is to illustrate the use of FRACTURE sequences in various contexts, including osteoarticular infection, inflammatory arthropathy, bone tumors, fractures, and crystal deposition diseases.

Indexed as

Bone and bonesJointsMagnetic resonance imagingMultidetector computed tomography

Identifiers

PMID40061096
PMCPMC11887474

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.