Evidence map›Paper›PMID 40052436›Full record

ArticleClinical and experimental dental research2025

Impact of Autoclaving on the Dimensional Stability of 3D-Printed Guides for Orthodontic Mini-Implant Insertion - An In Vitro Study.

Samuel David, Mira Hüfner, Nicole Rauch, Robert Kerberger, Dieter Drescher, Giulia Brunello, Kathrin Becker

Erratum issuedAbstract read
In one paragraph

Article in Clinical and experimental dental research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Samuel DavidDepartment of Orthodontics, University Hospital of Düsseldorf, Düsseldorf, Germany.
Mira HüfnerDepartment of Orthodontics, University Hospital of Düsseldorf, Düsseldorf, Germany.
Nicole RauchDepartment of Oral Surgery, University of Düsseldorf, Düsseldorf, Germany.
Robert KerbergerDepartment of Orthodontics and Dentofacial Orthopaedics, Charité - Universitätsmedizin, Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
Dieter DrescherDepartment of Orthodontics, University Hospital of Düsseldorf, Düsseldorf, Germany.
Giulia BrunelloDepartment of Oral Surgery, University of Düsseldorf, Düsseldorf, Germany.
Kathrin BeckerDepartment of Orthodontics and Dentofacial Orthopaedics, Charité - Universitätsmedizin, Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.

Funding

The authors received no specific funding for this work.
6 · The paper itself

Abstract

objectivesThis study aimed to assess the effect of the printing process itself and steam autoclaving on the geometrical stability of 3D-printed guides for mini-implant insertion. MATERIAL AND

methodsFifty guides (n = 10 per group) were printed with five printer/resin combinations (PRCs) from the same STL file using either digital light processing (DLP/EG, DLP/Next, DLP/Opti), desktop stereolithography (SLA/DSG) or liquid crystal display stereolithography printers (LCD/Amber). Half were sterilized by steam autoclaving with Cycle 1 (121°C, 1 bar, 20.5 min), half with Cycle 2 (134°C, 2 bars, 5.5 min). Before (T0) and after sterilization (T1) the guides were scanned with a structured light 3D scanner, and selected guides also with micro-CT for validation. Linear measurements were performed in three axes on STL, and on T0 and T1 scans. Linear mixed-effects models were used, followed by post-hoc tests in case of significance.

resultsMeasurements at T0 and T1 differed significantly from STL in both x- and y-axis (4 and 3 PRCs, respectively) (p < 0.05); in z-axis only DLP/Next showed significant differences between T0 and STL (p < 0.001). The comparison between T0 and T1 revealed significant differences in x-axis for DLP/Next and DLP/Opti after Cycle 1 and Cycle 2, respectively (p < 0.05), while in the y-axis no intra-group difference was recorded. In the z-axis all PRCs except for SLA/DSG exhibited significant shrinkage (for Cycles 1 or 2). Differences between the two cycles at T1 were registered only in z-axis (DLP/Next and LCD/Amber).

conclusionsCompared with the original, all PRCs except for SLA/DSG presented significant changes in their dimensional stability owing to the printing process itself and/or the sterilization. If these changes are of clinical significance, they remain to be verified. CLINICAL RELEVANCE: With the utilized design, the guides fabricated with SLA provided lower dimensional changes as compared to the ones produced by the other printing techniques.

Indexed as

Dental ImplantsOrthodontic Anchorage ProceduresPrinting, Three-DimensionalSterilizationHumansIn Vitro TechniquesSteamStereolithographyX-Ray MicrotomographyDental ImplantsSteam3D printinginsertion guidemicro‐CToptical 3D scannersterilization

Identifiers

PMID40052436
PMCPMC11886601

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.