Evidence map›Paper›PMID 40051887›Full record

ArticleGastroenterology research2025

Analysis of Adverse Events of Endoscopic Ultrasound-Guided Lumen-Apposing Metal Stent Placement: Insights Across Various Indications and Techniques.

Mohammed Abusuliman, Taher Jamali, Faisal Nimri, Ammad Javaid Chaudhary, Khaled Elfert, Abdulmalik Saleem, Ahmad Alomari, Muhammad Saad Faisal, Omar Shamaa, Mark Obri and 9 more

Abstract read
In one paragraph

Article in Gastroenterology research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors.

Mohammed AbusulimanDepartment of Internal Medicine-Henry Ford Hospital, Detroit, MI, USA.
Taher JamaliDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Faisal NimriDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Ammad Javaid ChaudharyDepartment of Internal Medicine-Henry Ford Hospital, Detroit, MI, USA.
Khaled ElfertDepartment of Gastroenterology, West Virginia University, Morgantown, WV, USA.
Abdulmalik SaleemDepartment of Internal Medicine-Henry Ford Hospital, Detroit, MI, USA.
Ahmad AlomariDepartment of Internal Medicine-Henry Ford Hospital, Detroit, MI, USA.
Muhammad Saad FaisalDepartment of Internal Medicine-Henry Ford Hospital, Detroit, MI, USA.
Omar ShamaaDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Mark ObriDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Ahmed E SalemDepartment of Internal Medicine, Maimonides Medical Center, Brooklyn, NY, USA.
Amr AbusulimanFaculty of Medicine, Tanta University, Tanta, Egypt.
Andrew WatsonDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Robert PompaDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Duyen DangDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Cyrus PirakaDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Mazen ElatracheDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Sumit SinglaDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.
Tobias ZuchelliDepartment of Gastroenterology, Henry Ford Hospital, Detroit, MI, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Endoscopic ultrasound (EUS)-guided lumen-apposing metal stent (LAMS) placement is increasingly being used Methods: A single-center retrospective cross-sectional study was conducted on patients who underwent EUS-guided LAMS placement between 2015 and 2023 at a single institution. Technical and clinical success rates and rates of early and late AEs were analyzed. Comparisons of AE rates were determined for patients who had LAMS dilation versus those without dilation, patients who had plastic stent placement in addition to LAMS placement versus those with no plastic stents, and patients who had combined dilation and plastic stent procedures versus those with LAMS dilation only. Results: A total of 243 patients underwent EUS-guided LAMS interventions: 110 (45.3%) women and 133 (54.7%) men (mean age 53.7 ± 15.9 years). There were 96 (39.5%) patients who had at least one AE. Abdominal pain was the most common early and late AE. Plastic stent placement alongside LAMS placement was associated with a significantly higher rate of overall AEs (48.3% vs 29.9%; P = 0.009), late AEs (33% vs 17.9%; P = 0.021), and stent occlusion (5.7% vs 0%; P = 0.046). LAMS dilation was associated with higher rates of late AEs (34.2% vs 20.6%; P = 0.022) and stent occlusion (6.2% vs 1.0%; P = 0.049). Conclusions: LAMS placement showed high technical and clinical success rates across different indications with mostly mild AEs, suggesting that LAMSs may be safe and effective for pancreatic and biliary drainage.

Indexed as

Adverse eventsEndoscopic ultrasoundLumen-apposing metal stent

Identifiers

PMID40051887
PMCPMC11882228

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.