Evidence map›Paper›PMID 40051846›Full record

ArticleHeliyon2025

Optimizing the design of a pediatric blood pump through orthogonal experimentation.

Kaiyun Gu, Kaiyue Yang, Changlong Zhao, Qiang Shu, Ru Lin

Abstract read
In one paragraph

Article in Heliyon, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Orthogonal design-drivenRSC advances · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kaiyun GuDepartment of Cardiac Surgery, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou, China.
Kaiyue YangDepartment of Innovation Center for Child Health, Binjiang Institute of Zhejiang University, Hangzhou, China.
Changlong ZhaoDepartment of Innovation Center for Child Health, Binjiang Institute of Zhejiang University, Hangzhou, China.
Qiang ShuDepartment of Cardiac Surgery, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou, China.
Ru LinDepartment of Cardiac Surgery, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Pediatric heart failure patients weighing less than 30 kg are prioritized for small axial flow blood pumps due to their smaller body size. This study aims to optimize the blade design of pediatric axial flow blood pumps by conducting orthogonal experiments on blade parameters and integrating hydraulic experiments with hemodynamic numerical simulations, so as to improve the hydraulic performance of pediatric blood pumps while reducing blood damage. Methods: This study employs a combination of computational fluid dynamics (CFD) and orthogonal experimentation to optimize six key parameters of the impeller blade. The optimal blade parameter model is determined through range analysis. The hydraulic performance of the optimized model is evaluated via in vitro experiments, which provide pressure and flow data. Additionally, hemodynamic performance is assessed using CFD, with key evaluation indices including flow field characteristics, pressure distribution, and shear stress distribution within the axial flow pump. Results: From an orthogonal experiment, six blade parameters were found to influence blood pump pressure head: the distance between the starting surface of the blade and the hub (W), blade height (h), blade length (L), blade wrapping angle (α), blade outlet angle (β), and blade inlet angle (γ). The approximately linear pressure-flow curve of the optimized axial blood pump meets design requirements at a pump speed of 10000 rpm, achieving a pressure head of 50.8 mmHg and a flow rate of 3L/min. Computational fluid dynamics analysis reveals a smooth flow field with a low maximum reflux rate of 0.16 % in sections I, II, and III. Pressure is evenly distributed, with a maximum of approximately 10 Conclusions: This study investigates the correlation between blade parameters and hydraulic performance in axial flow pumps used for blood pumping. The results of both flow field analysis and experimental studies, conducted using orthogonal experiments, demonstrate that the optimized blood pump exhibits enhanced performance in reducing both reflux rate and shear stress. These findings provide valuable insights for the design optimization of pediatric ventricular assist devices.

Indexed as

Axial blood pumpBlade parametersHemodynamicsOrthogonal experimentPediatric heart failure

Identifiers

PMID40051846
PMCPMC11883357

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked