Evidence map›Paper›PMID 40050390›Full record

ArticleScientific reports2025

A modified measurement method for functional spinal unit ROM of cervical spine.

Jianxi Wang, Hao Zhou, Bo Hu, Fazhi Zang, Wen Yuan, Huajiang Chen, Lei Liang

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jianxi Wang *Department of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China.
Hao Zhou *Department of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China.
Bo Hu *Department of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China.
Fazhi ZangDepartment of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China.
Wen YuanDepartment of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China. yuanwenspine@smmu.edu.cn.
Huajiang ChenDepartment of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China. spine.chen@163.com.
Lei LiangDepartment of Orthopedics, Changzheng Hospital, Naval Medical University, 415 Feng Yang Road, Shanghai, 200003, People's Republic of China. dr.winlych@163.com.

Funding

Naval Medical University Research Project 2022MS031
6 · The paper itself

Abstract

The interspinous process motion (ISM) method can provide a more accurate assessment of postoperative subaxial cervical fusion than Cobb angle method which is used more commonly in clinical practice. However, the ISM method presents the measurement results in millimeters which cannot be directly compared with the Cobb angle measurement data. We proposed a modified measurement method for cervical functional spinal unit range of motion  (FSU ROM) and evaluate its repeatability and reliability in measuring the ROM of the surgical segment after cervical artificial disc replacement surgery. A total of 81 patients who underwent cervical artificial disc replacement surgery in our department were retrospectively reviewed. Postoperative flexion-extension dynamic cervical radiographs were used for the measurement of FSU ROM of the surgical segment. The modified measurement method (M1) and the traditional Cobb angle measurement method (M2) were used. In the comparative analysis, there was no statistically significant difference between the two measurement methods (P > 0.05). Linear correlation study showed significant correlation between the two methods (P < 0.01), with a correlation coefficient of 0.947. Bland-Altman analysis showed the average difference between the two methods was 0.13°, the most of the measured data points fell within the 95% confidence interval. The M1 method demonstrated high intra-observer reliability (ICC = 0.957) and inter-observer reliability (ICC = 0.947). The M2 method showed good intra-observer reliability (ICC = 0.889) and good inter-observer reliability (ICC = 0.874). The M1 method yielded an SEM of 0.64° and an MDC of 1.49° for FSU ROM measurement, while the M2 method resulted in an SEM of 1.14° with an MDC of 2.66°.The modified measurement method for assessing cervical FSU ROM demonstrates satisfactory repeatability and reliability, provide higher measurement precision.

Indexed as

Cervical VertebraeImage Processing, Computer-AssistedRange of Motion, ArticularAdultFemaleHumansMaleMiddle AgedObserver VariationRadiographyRecovery of FunctionReproducibility of ResultsSpinal FusionCervical spineCobb AngleMeasurement methodROM

Identifiers

PMID40050390
PMCPMC11885802

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.