Evidence map›Paper›PMID 40049732›Full record

ArticleInternational journal of spine surgery2025

Novel Instruments for Full Endoscopic Trans-Kambin Triangle Lumbar Interbody Fusion With Reverse Oblique Lateral Cage Insertion: A Case Report and Technical Note.

Wei-Lun Chang, Jou-Hua Wang, Ming-Long Yeh, Jui-Ming Yang

Abstract read
In one paragraph

Article in International journal of spine surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wei-Lun ChangDepartment of Surgery, Division of Orthopedics, National Cheng Kung University Hospital DouLiou Branch, National Cheng Kung University, Yunlin, Taiwan.
Jou-Hua WangDepartment of Surgery, Division of Orthopedics, National Cheng Kung University Hospital DouLiou Branch, National Cheng Kung University, Yunlin, Taiwan.
Ming-Long YehDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Jui-Ming YangDepartment of Orthopedics, Department of Surgery, Sin-Lau Christian Hospital, Tainan, Taiwan jmyang25@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLumbar interbody fusion with screw fixation is a standard treatment for lumbar degenerative diseases. While full-endoscopic lumbar interbody fusion is minimally invasive, it utilizes smaller cages compared with the oblique lateral interbody fusion (OLIF) technique, which offers superior biomechanical support. To merge full-endoscopic lumbar interbody fusion minimal invasiveness with OLIF's advantages, we developed a novel instrument, the Single Beak Adjustable Cage Glider, to facilitate OLIF cage insertion via the full-endoscopic trans-Kambin triangle approach. This note and case report introduce this alternative solution. CASE PRESENTATION: In a case of L4 to L5 spondylolisthesis, we performed fluoroscopy-guided uniportal facet-preserving trans-Kambin endoscopic fusion surgery. We initially installed percutaneous pedicle screws and rods to correct the anterolisthesis, then established the endoscopic trans-Kambin approach. After releasing the disc-endplate junction, the nerve root was mobilized and protected by the beak of the cage glider. The disc space was cleared, and a 22 × 40 × 12 mm interbody device was inserted through the cage glider under fluoroscopic guidance. The integrity of the exiting nerve root was confirmed with an endoscope.

resultsPostoperatively, the patient experienced significant improvements in both low back pain and bilateral lower limb numbness. Muscle strength in both lower limbs returned to baseline, and the patient was able to walk independently without assistive devices. Follow-up radiographs and computed tomography scans showed a well-reduced regional lordotic angle, and the axial computed tomography view confirmed adequate decompression of the spinal canal while preserving the facet joints.

conclusionsThe Single Beak Adjustable Cage Glider enables precise positioning of the OLIF cage through the Kambin triangle lumbar interbody fusion approach, avoiding nerve root injury and preserving facet joints. This technique reduces surgical trauma and maintains spine biomechanics, potentially improving patient outcomes. CLINICAL RELEVANCE: This technique potentially reduces the cage subsidence rate. LEVEL OF EVIDENCE: 5:

Indexed as

degenerative spinal diseaseendoscopic fusion surgeryfull-endoscopic-KLIFnovel spine techniquereverse oblique lateral interbody fusion

Identifiers

PMID40049732
PMCPMC12053264

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.