ArticleMagnetic resonance imaging2025

A single oscillating waveform-based gradient delay estimation.

Bo Li, Xiao Liang, Manuel Taso, Yulin Chang, John A Detre, Ze Wang

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bo LiDepartment of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States.
Xiao LiangDepartment of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States.
Manuel TasoSiemens Medical Solutions USA Inc, Malvern, PA, United States.
Yulin ChangSiemens Medical Solutions USA Inc, Malvern, PA, United States.
John A DetreDepartment of Neurology, University of Pennsylvania, Philadelphia, PA, United States.
Ze WangDepartment of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States. Electronic address: ze.wang@som.umaryland.edu.

Funding

QAQC Johns Hopkins Institute for Clinical and Translational ResearchUL1TR003098 · NCATS · JOHNS HOPKINS UNIVERSITY · PI FORD, DANIEL ERNEST · 2019 to 2023
$57.7M
Academic Industrial Partnership on Advanced Perfusion MRIR01EB031080 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI Yulin V Chang, JOHN A DETRE · 2022 to 2026
$2.7M
Diversity Supplement to Brain entropy mapping in Alzheimer's DiseaseR01AG070227 · NIA · UNIVERSITY OF MARYLAND BALTIMORE · PI WANG, ZE · 2021 to 2024
$2.5M
Deep-Learning Enhanced ASL MRI For Early AD AssessmentR01AG081693 · NIA · UNIVERSITY OF MARYLAND BALTIMORE · PI Ze Wang · 2024 to 2026
$2.3M
Assessing ASL CBF as a biomarker for early Alzheimer's disease detection and disease progressionR01AG060054 · NIA · UNIVERSITY OF MARYLAND BALTIMORE · PI WANG, ZE · 2019 to 2021
$1.7M
Automated Quality Evaluation and Harmonization for Multisite ASL MRI DataR21AG080518 · NIA · UNIVERSITY OF PENNSYLVANIA · PI DOLUI, SUDIPTO, WANG, ZE · 2023 to 2024
$453k
NCATS NIH HHS UL1 TR003098NIA NIH HHS R01 AG060054NIA NIH HHS R01 AG070227NIA NIH HHS R01 AG081693NIA NIH HHS R21 AG080518NIBIB NIH HHS R01 EB031080
6 · The paper itself

Abstract

purposeWe present a time efficient method to estimate gradient delay using a single oscillating waveform.

methodsSingle oscillating waveform-based gradient delay estimation algorithm (SODA) was proposed. It estimated gradient delays by measuring the relative shifts of echoes acquired at consecutive time points. An acceleration was achieved by a three spin-echo sequence acquiring measurements for all gradient channels within a single excitation. Simulations and phantom experiments were carried out to compare SODA with a reference method. In addition, we monitored the change of the gradient delay over time using an integrated sequence with high gradient amplitude on a 3 T scanner. High-resolution imaging was performed for phantom and in vivo studies to compare images quality with and without gradient delay correction (GDC).

resultsSimulations showed no significant difference in gradient delay estimates when comparing SODA with the reference method for noise levels 1 to 5. The phantom results confirmed strong agreements on delay estimates between SODA with the three spin-echo sequence and the reference method with six pulse repetitions. The gradient delays were observed nearly consistent over time for the scanner. For high-resolution imaging, the reconstruction with GDC exhibit sharper and clearer depictions of images structures than reconstruction without GDC.

conclusionSODA can provide accurate gradient delay estimates with short calibration scan time. The three spin-echo sequence can be seamlessly integrated with any host sequence to measure the gradient delay and provide accurate spiral trajectory. It may be a valuable tool for gradient delay correction in spiral imaging.

Indexed as

AlgorithmsBrainImage Interpretation, Computer-AssistedMagnetic Resonance ImagingComputer SimulationHumansImage EnhancementImage Processing, Computer-AssistedPhantoms, ImagingReproducibility of ResultsGradient delay estimationpCASLSingle-waveform methodSODASpiral

Identifiers

PMID40049252
PMCPMC12168186

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.