ArticleJournal of applied clinical medical physics2025
Multi-institutional study on image quality for a novel CBCT solution on O-ring linac.
Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Workflow and dosimetric results for direct-to-unit single-fraction adaptive lung SBRT delivered on the ONE-STOP prospective pilot clinical trial.Clinical and translational radiation oncology · 2026Article
- Quantitative stability of CT numbers in novel cone-beam CT: An intra-institution cross-scanner and longitudinal analysis.Journal of applied clinical medical physics · 2026Article
- Structure visibility and online adaptation suitability of a new high-performance ring-gantry cone-beam computed tomography imaging system in thoracic radiotherapy.Physics and imaging in radiation oncology · 2026Article
- Simulated online adaptive radiotherapy on C-arm linacs: Integrating high resolution cone-beam CT into abdominal stereotactic body radiation therapy.Journal of applied clinical medical physics · 2026Article
- Multi-institutional validation of hypersight CBCT-based dose calculation on O-ring linacs.Journal of applied clinical medical physics · 2026Article
- A clinical evaluation of HyperSight CBCT enhanced offline adaptive breast radiotherapy.Frontiers in oncology · 2026Article
- Correlation between exposure (mAs) and image quality for a rapid cone-beam CT on a ring gantry linear accelerator.Journal of applied clinical medical physics · 2025Article
- Comparison of cone beam computed tomography post-processing methods for online adaptive proton therapy of prostate cancer.Physics and imaging in radiation oncology · 2025Article
- Multi-institutional study on image quality for a novel CBCT solution on O-ring linac.Journal of applied clinical medical physics · 2025Article
- Multi-institutional Comparison of Novel O-ring Linac Cone Beam Computed Tomography with Fan Beam Computed Tomography.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThis work presents a multi-institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
methodsPhantoms for measuring relative electron density (RED) and image quality were sent to six institutions for imaging on Ethos and Halcyon units equipped with HyperSight CBCT. The imaging protocols included tube potential from 100 to 140 kVp and exposure from 80 to 800 mAs. Imaging performance was evaluated with regard to RED versus Hounsfield units (HU), uniformity, contrast-to-noise ratio (CNR), slice thickness, circular symmetry, modulation transfer function (MTF), and spatial resolution.
resultsAmong all institutions, some variability was observed among institutions in the RED-to-HU relationship, especially for RED values greater than 1, although no outliers were found (|z-score| < 2 in all cases). In this range, RED/HU slopes were 475 ± 25 10
conclusionsThis multi-institutional analysis of CBCT imaging performance showed consistency in radial uniformity, circular symmetry, integral nonuniformity, contrast, and spatial resolution. Some variability was seen in the RED-to-HU relationship for RED > 1 depending on exposure. More data from different institutions would be necessary to establish more robust statistical metrics, which ensure quality parameters.