ArticleMicromachines2025
A Versatile SAW Sensor-Based Modular and Portable Platform for a Multi-Sensor Device.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Detection of Irregular Loads Using SAW Delay-Line Devices.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
This study presents the development and characterization of a novel electronic nose system based on customized surface acoustic wave (SAW) sensors. The system includes four sensors, customized with different custom polymer coatings, in order to detect volatile organic compounds (VOCs). The main innovation lies in the design of a robust and versatile switching electronics system that allows for the integration of the SAW sensors into portable systems, as well as interoperability with other gas sensor technologies. The system includes a modular architecture that allows multiple sensor arrays to be combined to improve the selectivity and discrimination of complex gas mixtures. To verify the proper performance of the system and the detection capability of the manufactured sensors, experimental laboratory tests have been carried out. Specifically, ethanol and acetone measurements up to a 2000 ppm concentration have been performed. These preliminary experimental results demonstrate the capability of the SAW sensors with different response patterns across the sensor array. In particular, the sensor made with the polyvinyl acetate polymer exhibits high sensitivity to both VOCs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.