Evidence map›Paper›PMID 40046959›Full record

ArticleFrontiers in cardiovascular medicine2025

Clinical performance of subcutaneous vs. transvenous implantable defibrillator in patients with ischemic cardiomyopathy:

Vincenzo Russo, Alfredo Caturano, Valter Bianchi, Anna Rago, Ernesto Ammendola, Andrea Antonio Papa, Nadia Della Cioppa, Annamaria Guarino, Alessandro Masi, Antonio D'Onofrio and 3 more

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Vincenzo Russo *Division of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Alfredo Caturano *Department of Advanced Medical and Surgical Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Valter BianchiDepartmental Unit of Electrophysiology, Evaluation and Treatment of Arrhythmias, Monaldi Hospital, Naples, Italy.
Anna RagoDivision of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Ernesto AmmendolaDivision of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Andrea Antonio PapaDivision of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Nadia Della CioppaDepartment of Anesthesiology, Monaldi Hospital, Napoli, Italy.
Annamaria GuarinoDepartment of Anesthesiology, Monaldi Hospital, Napoli, Italy.
Alessandro MasiDivision of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Antonio D'OnofrioDepartmental Unit of Electrophysiology, Evaluation and Treatment of Arrhythmias, Monaldi Hospital, Naples, Italy.
Paolo GolinoDivision of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.
Emilio Di LorenzoDepartment of Cardiology, AORN dei Colli-Monaldi Hospital, Naples, Italy.
Gerardo NigroDivision of Cardiology, Department of Medical Translational Sciences, University of Campania Luigi Vanvitelli, Naples, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Subcutaneous ICD (S-ICD) is an alternative to a transvenous implantable cardioverter-defibrillator (TV-ICD) system in selected patients not in need of pacing or resynchronization. Currently, little is known about the effectiveness and safety of S-ICD in patients with ischemic cardiomyopathy (ICM). The aim of our study was to describe the clinical features and the drivers of S-ICD implantation among patients with ICM, as well as the clinical performance of S-ICD vs. TV-ICD among this subset of patients during a long-term follow-up. Materials and methods: All ICM patients with both S-ICD and TV-ICD implanted and followed at Monaldi Hospital from January 1, 2015, to January 1, 2024, were evaluated; among them, only ICD recipients with no pacing indication were included. We collected clinical and anamnestic characteristics, as well as ICD inappropriate therapies, ICD-related complications and infections. Results: A total of 243 ICM patients (mean age 63.0 ± 11.0, male 86.0%) implanted with TV-ICD ( Conclusions: Among patients with ICM not in need of pacing or resynchronization (CRT), the decision to implant an S-ICD was primarily influenced by female gender and primary prevention indications. No significant differences in inappropriate ICD therapies and complications were found; in contrast, the S-ICD group showed a numerically reduced risk of ICD-related infections.

Indexed as

complicationsinappropriate shock therapyinfectionsischemic cardiomyopathysubcutaneous ICD (S-ICD)transvenous ICD

Identifiers

PMID40046959
PMCPMC11880277

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.