Evidence map›Paper›PMID 40046615›Full record

ArticleACS applied polymer materials2025

Design and Application of an Imprinted Polymer Sensor for the Dual Detection of Antibiotic Contaminants in Aqueous Samples and Food Matrices.

Oliver D Jamieson, Jérémy Bell, Alexander Hudson, Joshua Saczek, Victor Pérez-Padilla, Gustavo Kaiya, Katarina Novakovic, Matthew Davies, Emma Foster, Jonas Gruber and 2 more

Abstract read
In one paragraph

Article in ACS applied polymer materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Oliver D JamiesonDepartment of Chemical Engineering and Analytical Science, School of Engineering, University of Manchester, Manchester M13 9QS, U.K.
Jérémy BellChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Straße 11, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0003-1861-1670
Alexander HudsonSchool of Engineering, Newcastle University, Merz Court, Claremont Road, Newcastle Upon Tyne NE1 7RU, U.K.
Joshua SaczekDepartment of Chemical Engineering and Analytical Science, School of Engineering, University of Manchester, Manchester M13 9QS, U.K.
Victor Pérez-PadillaChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Straße 11, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0001-6244-7439
Gustavo KaiyaDepartamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo CEP 05508-000, São Paulo, Brazil.
Katarina NovakovicSchool of Engineering, Newcastle University, Merz Court, Claremont Road, Newcastle Upon Tyne NE1 7RU, U.K.
Matthew DaviesSchool of Engineering, Newcastle University, Merz Court, Claremont Road, Newcastle Upon Tyne NE1 7RU, U.K.
Emma FosterNewcastle University, Bioimaging Unit, Leech Building, Framlington Place, Newcastle Upon Tyne NE2 4HH, U.K.
Jonas GruberDepartamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo CEP 05508-000, São Paulo, Brazil.ORCID https://orcid.org/0000-0003-2832-0199
Knut RurackChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Straße 11, 12489 Berlin, Germany.ORCID https://orcid.org/0000-0002-5589-5548
Marloes PeetersDepartment of Chemical Engineering and Analytical Science, School of Engineering, University of Manchester, Manchester M13 9QS, U.K.ORCID https://orcid.org/0000-0002-0429-8073

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An innovative polymer-based dual detection microfluidic platform has been developed for the accurate and reliable sensing of trace amounts of antibiotic tetracycline in environmental and food samples. This was achieved through the production of a bespoke polymeric material formed via an imprinting technique using a fluorescent dye. Thus, this enables dual detection of tetracycline, both thermally, via analyzing the heat-transfer resistance at the solid-liquid interface, and optically, through the inner filter effect. The combination of these two methods achieved a nanomolar limit of detection for tetracycline while also providing rapid, selective, and cost-effective sensing. Additionally, this method successfully detected tetracycline levels of 0.56 μM in blank egg samples which was significantly lower than the maximum residual level of 400 μg L

Identifiers

PMID40046615
PMCPMC11877416

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.