Evidence map›Paper›PMID 40042685›Full record

ArticleJournal of materials science. Materials in medicine2025

Electromagnetic induction disinfection applied to cemented knee arthroplasty implants: safety evaluation of potential changes in the bone cement.

Enrique Cordero García-Galán, Francisco Javier Medel Rezusta, Héctor Sarnago, José M Burdio, Óscar Lucía, Jaime Esteban, Enrique Gómez-Barrena

Abstract read
In one paragraph

Article in Journal of materials science. Materials in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Enrique Cordero García-Galán *Dept. of Orthopaedic Surgery and Traumatology, Hospital Universitario Príncipe de Asturias, Av Principal de la Universidad s/n, 28805, Alcalá de Henares, Madrid, Spain. enriquecorderogg@gmail.com.
Francisco Javier Medel Rezusta *Dept. of Mechanical Engineering. I3A. Escuela de Ingeniería y Arquitectura, Universidad de Zaragoza, Zaragoza, Spain.
Héctor SarnagoDepartment of Electronic Engineering and Communications. I3A, Universidad de Zaragoza, Zaragoza, Spain.
José M BurdioDepartment of Electronic Engineering and Communications. I3A, Universidad de Zaragoza, Zaragoza, Spain.
Óscar LucíaDepartment of Electronic Engineering and Communications. I3A, Universidad de Zaragoza, Zaragoza, Spain.
Jaime EstebanDept. of Clinical Microbiology, IIS-Fundacion Jimenez Diaz, UAM, Av. Reyes católicos 2, 28040, Madrid, Spain.
Enrique Gómez-BarrenaDept of Orthopaedic Surgery and Traumatology. Hospital La Paz-IdiPAZ, Universidad Autónoma de Madrid, Madrid, Spain.ORCID http://orcid.org/0000-0001-8103-703X

Funding

Fundación Mutua Madrileña FMMA2020 GOMEZ BARRENA
6 · The paper itself

Abstract

backgroundElectromagnetic induction heating is a newly developed disinfection method aimed at improving periprosthetic infection outcomes after Debridement and Implant Retention (DAIR). One safety concern is its effect over polymethylmethacrylate (PMMA). The objective of this in-vitro study is to assess such effect on cement adjacent to metallic arthroplasty components.

methodsTwo different PMMA products, with and without antibiotic, were applied on three total-knee arthroplasty implants. A portable device was used to administer induction-heating protocols: 70 °C, 3.5 min and 100 °C, 3.5 min, while the third prosthesis served as control. The 602 cm

resultsIsotactic/syndiotactic ratios were 0.27(±0.02) for antibiotic-free cement, and 0.41(±0.02) for gentamicin-loaded cement. After induction-heating protocols, isotactic fraction increased in antibiotic-free cement, and decreased in gentamicin-loaded cement. No evidence of crystallization was found in ATR-FTIR, except for a small increase in 1340 cm

conclusionsSpectroscopic techniques confirmed that PMMA only experienced minor structural changes after induction heating treatments. From a structural viewpoint, these results suggest that electromagnetic induction heating could be a safe disinfection technique for cemented implants in total knee arthroplasty.

Indexed as

Arthroplasty, Replacement, KneeBone CementsDisinfectionKnee ProsthesisAnti-Bacterial AgentsElectromagnetic PhenomenaGentamicinsHumansMaterials TestingPolymethyl MethacrylateProsthesis-Related InfectionsSpectroscopy, Fourier Transform InfraredSpectrum Analysis, RamanAnti-Bacterial AgentsBone CementsGentamicinsPolymethyl Methacrylate

Identifiers

PMID40042685
PMCPMC11882642

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.