Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Graham B J BuchanDepartment of Orthopaedic Surgery, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Christian J HechtDepartment of Orthopaedic Surgery, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Mary NugentDepartment of Orthopaedic Surgery, Te Whatu Ora (Health New Zealand) Lakes, Rotorua Hospital, Rotorua, New Zealand.
Nathanael D HeckmannDepartment of Orthopaedic Surgery, Adult Reconstruction Division, Keck School of Medicine of USC, Los Angeles, CA, USA.
Arihiko KanajiFujita Health University Bantane Hospital, Nagoya, Aichi, Japan.
Atul F KamathDepartment of Orthopaedic Surgery, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA. akamath@post.harvard.edu.ORCID http://orcid.org/0000-0002-9214-2756

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOptimizing leg length discrepancy (LLD) and restoring global and femoral offset (GO, FO) are integral to improving the stability and longevity of total hip arthroplasty (THA). A novel robotic-assisted THA (RA-THA) platform has been developed to utilize pre-operative templating and intraoperative fluoroscopic imaging to guide the restoration of native biomechanics. We sought to evaluate the effectiveness of this novel, pin-less, fluoroscopy-based RA-THA system to restore templated LLD and offset parameters. MATERIALS AND

methodsWe performed a retrospective analysis on a consecutive series of 98 patients who underwent fluoroscopy-based RA-THA at our institution. The primary outcomes were the differences between preoperatively templated LLD, GO, and FO parameters with intraoperatively achieved parameters measured by the robotic system and with postoperatively achieved parameters measured from postoperative radiographs.

resultsThe mean difference between achieved and preoperatively templated values of LLD (-1.5 ± 5.5 mm), GO (-0.1 ± 5.5 mm), and FO (-0.1 ± 5.4 mm) were all within - 1.5 mm of establishing equalized leg length and offset. The proportion of patients with a difference in achieved and templated values < 10 mm were 92% for LLD, 91% for GO, and 93% for FO. For 43 of the 98 (44%) patients in this study, the surgeon referenced intraoperative robotic data to adjust femoral components from the preoperative plan in order to optimize LLD and offset parameters.

conclusionsThe results of our present study demonstrated that fluoroscopy-based RA-THA is associated with high levels of accuracy in restoring key biomechanics of the hip. In a large number of patients, the surgeon used intraoperative robotic data to more closely achieve LLD and offset goals. This demonstrates the ability of this system to merge preoperative data with intraoperative, actionable data provided by the robotic software to restore leg length and global/femoral offset parameters. Words: 279/ 300.

Indexed as

Arthroplasty, Replacement, HipLeg Length InequalityRobotic Surgical ProceduresAdultAgedFemaleFluoroscopyHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeFemoral offset (FO), global offset (GO)Limb length discrepancy (LLD)Robotic-assisted surgeryTotal hip arthroplasty (THA)

Identifiers

PMID40042653

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.