Evidence map›Paper›PMID 40042596›Full record

ArticleLangmuir : the ACS journal of surfaces and colloids2025

Optical and Acoustic Characterization of Phase-Shift Droplets with Varying Shell Compositions.

Sugandha Chaudhary, Anuj Kaushik, Bachir A Abeid, Jonathan B Estrada, Mario L Fabiilli, Mitra Aliabouzar

Abstract read
In one paragraph

Article in Langmuir : the ACS journal of surfaces and colloids, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sugandha ChaudharyDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
Anuj KaushikDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
Bachir A AbeidDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.ORCID 0009-0009-0859-8434
Jonathan B EstradaDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
Mario L FabiilliDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.ORCID 0000-0002-4752-9812
Mitra AliabouzarDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.ORCID 0000-0002-2263-7278

Funding

Angiogenic growth factor delivery for vascular regeneration in critical limb ischemia using acoustically-responsive scaffoldsR01HL139656 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Mario Leonardo Fabiilli · 2018 to 2026
$5.7M
NHLBI NIH HHS R01 HL139656
6 · The paper itself

Abstract

Shell-stabilized, phase-shift droplets of perfluorocarbon have shown promising potential in diagnostic and therapeutic ultrasound applications. While the role of shell composition has been well-studied for conventional gas-filled microbubbles, its influence on bubbles generated via acoustic droplet vaporization (ADV) remains understudied. This study investigates the effect of shell composition─lipid, protein, and polymer─on the stability, ADV dynamics, growth behavior, release kinetics, and acoustic response of perfluorohexane phase-shift droplets. Payload-carrying, micron-sized droplets were produced using a microfluidic platform. Both optical, including ultrahigh-speed and timelapse confocal microscopy, and acoustic characterizations of the generated droplets were investigated in fibrin-based, tissue-mimicking hydrogels. Fluorescent markers were used to selectively label fibrin, payload, and droplet shells. Following insonation at 2.5 and 9.6 MHz, lipid-coated droplets had a maximum expansion ratio up to 20% lower than protein- and polymer-coated droplets. Payload release rates were an order of magnitude faster than the bubble growth rate post ADV, with minimal dependence on shell composition. Additionally, lipid shell fluorescence retained up to 40% of its initial intensity 120 s after ADV, while protein shell fluorescence was completely diminished. Acoustic characterization indicated that the ADV and inertial cavitation thresholds were similar across all shell types, suggesting that shell composition has a negligible effect on acoustic characteristics at high driving pressures.

Indexed as

AcousticsFluorocarbonsHydrogelsMicrobubblesVolatilizationFluorocarbonsHydrogels

Identifiers

PMID40042596
PMCPMC12557268

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.