ArticleFrontiers in cardiovascular medicine2025
Optimized workflow for paroxysmal atrial fibrillation ablation using very high power short duration.
Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Pulsed-Field Ablation Versus Radiofrequency Ablation for Paroxysmal Atrial Fibrillation: A Systematic Review and Meta-Analysis.Journal of arrhythmia · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: wide antral pulmonary vein isolation (PVI) is effective for treating paroxysmal atrial fibrillation (PAF), although time-demanding. We investigated the impact of a standardized ablation protocol by using a bidirectional transeptal steerable sheath, high-density mapping and very high-power-short-duration (vHPSD) catheters on procedure timing, efficacy, and safety. Methods: consecutive PAF patients free from previous ablations undergoing PVI alone between January 2022 and March 2023 were prospectively enrolled. The standardized workflow included general anesthesia, a single transeptal puncture trough with a bidirectional, steerable visualizable sheath introduced into the left atrium accommodated a high density, penta-spline mapping catheter and a contact force sensor ablation catheter enabled to deliver vHPSD. Procedural data and electrophysiology (EP) laboratory times were systematically collected and analyzed. The primary endpoint was any AF or atrial tachycardia recurrence at 12 and 24 month follow up. Results: the study cohort was composed by 138 patients (mean age was 59 ± 11 years, 38% female) and successful PVI was achieved in 100% of cases. Overall, first pass isolation (PFI) was 93%, with a LA dwell time of 32 ± 4 min. Significant complications were reported in 3% of patients. Skin-to-skin time and total EP laboratory time were 58 ± 5 min and 85 ± 7 min, respectively. The primary endpoint was achieved by 9% and 12% of cases at 12 and 24 month follow up, respectively. Upper limit skin-to-skin time and missed FPI resulted predictors of the primary endpoint. Conclusion: This standardized workflow resulted in low procedural times and arrhythmias recurrence without compromising the safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.