ArticleEuropean heart journal. Imaging methods and practice2025
The impact of bicuspid valve morphology on the selection of transcatheter aortic valve implantation devices: an
Article in European heart journal. Imaging methods and practice, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Novel Self-Expanding Transcatheter Mitral Valve with Dual Annulus/Valve Diameter.Journal of functional biomaterials · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aims: Bicuspid aortic valve (BAV) represents a challenge for transcatheter aortic valve implantation (TAVI). Few data are reported about the procedural implications of BAV using different self-expandable devices. The aim of this study is to investigate how BAV and tricuspid aortic valve (TAV) morphologies influence device selection and their impact on the potential development of post-operative conduction disturbances, using a novel Methods and results: Five patients with BAV undergoing TAVI were enrolled. TAVs were virtually modelled within each BAV patient-specific anatomy, resulting in 10 virtual patients. Acurate Neo2 and Evolut R implantations were subsequently simulated across all cases. Post-implantation stresses exerted on both the stent and aortic root were measured, allowing a comparative analysis of the impact of the two valve morphologies. Comparing stent stresses between BAV and TAV configurations, the stress gap increased by 21.96 ± 5.35% ( Conclusion: Our patient-specific model shows that high radial force devices, such as Evolut R, demonstrate consistent expansion regardless of valve morphology, without increasing the risk of post-implantation conduction disturbances, hence resulting more suitable for BAV cases. Incorporating this methodology into pre-operative planning could support clinicians in selecting the most suitable device with a patient-specific approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.